CVE-2012-1799 The web server on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 does not limit the rate of authentication attempts, which makes it easier f...
HighCVSS 10.0
EPSS 5.0%
- Published
- Updated
- Exploit status
- No public exploit known
Description
The web server on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 does not limit the rate of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack on the administrative password.
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens scalance s firmware | <= 2.3.0 | No fix listed |
| Siemens scalance s firmware | = 2.1.0 | No fix listed |
| Siemens scalance s firmware | = 2.2.0 | No fix listed |
| Siemens scalance s602 | = v2 | No fix listed |
| Siemens scalance s612 | = v2 | No fix listed |
| Siemens scalance s613 | = v2 | No fix listed |
References
- 81033 vdb-entry
- support.automation.siemens.com
- www.siemens.com vendor-advisory
- www.us-cert.gov us-government-resource