Skip to content

CVE-2013-7312 The OSPF implementation on Enterasys switches and routers does not consider the possibility of duplicate Link State ID values in Link State Advertisement (LSA) packets before performing operations on....

MediumCVSS 5.4 EPSS 1.1%
Published
Updated
Exploit status
No public exploit known

Description

The OSPF implementation on Enterasys switches and routers does not consider the possibility of duplicate Link State ID values in Link State Advertisement (LSA) packets before performing operations on the LSA database, which allows remote attackers to cause a denial of service (routing disruption) or obtain sensitive packet information via a crafted LSA packet, a related issue to CVE-2013-0149.

Affected products

ProductAffected versionsFixed in
enterasys c5 All versions No fix listed
enterasys g3 All versions No fix listed
enterasys k10 All versions No fix listed
enterasys k6 All versions No fix listed
enterasys s130 All versions No fix listed
enterasys s140 All versions No fix listed
enterasys s150 All versions No fix listed
enterasys s155 All versions No fix listed
enterasys s180 All versions No fix listed

References