Skip to content

CVE-2015-4334 The default configuration of SGOS in Blue Coat ProxySG before 6.2.16.5, 6.5 before 6.5.7.1, and 6.6 before 6.6.2.1 forwards authentication challenges from upstream origin content servers (OCS) when us...

MediumCVSS 5.0 EPSS 3.3%
Published
Updated
Exploit status
No public exploit known

Description

The default configuration of SGOS in Blue Coat ProxySG before 6.2.16.5, 6.5 before 6.5.7.1, and 6.6 before 6.6.2.1 forwards authentication challenges from upstream origin content servers (OCS) when used in an explicit proxy deployment, which makes it easier for remote attackers to obtain sensitive information via a 407 (aka Proxy Authentication Required) HTTP status code, as demonstrated when using NTLM authentication.

Upgrade path

1 package: 1 fixed.

PackageAffectedFixed inStatus
symantec proxysg firmware >= 6.2, <= 6.2.16.4; >= 6.5, <= 6.5.7.0; >= 6.6, <= 6.6.2.0 after 6.2.16.4, 6.5.7.0, 6.6.2.0 Fixed

Affected products

ProductAffected versionsFixed in
symantec proxysg firmware >= 6.2, <= 6.2.16.4 No fix listed
symantec proxysg firmware >= 6.5, <= 6.5.7.0 No fix listed
symantec proxysg firmware >= 6.6, <= 6.6.2.0 No fix listed

References