CVE-2016-0917 The SMB service in EMC VNXe (VNXe3200 Operating Environment prior to 3.1.5.8711957 and VNXe3100/3150/3300 Operating Environment prior to 2.4.4.22638), VNX1 File OE before 7.1.80.3, VNX2 File OE before...
CriticalCVSS 9.8
EPSS 4.2%
- Published
- Updated
- Exploit status
- No public exploit known
Description
The SMB service in EMC VNXe (VNXe3200 Operating Environment prior to 3.1.5.8711957 and VNXe3100/3150/3300 Operating Environment prior to 2.4.4.22638), VNX1 File OE before 7.1.80.3, VNX2 File OE before 8.1.9.155, and Celerra (all supported versions) does not prevent duplicate NTLM challenge-response nonces, which makes it easier for remote attackers to execute arbitrary code, or read or write to files, via a series of authentication requests, a related issue to CVE-2010-0231.
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| emc vnx1 oe firmware | All versions | No fix listed |
| emc vnx2 oe firmware | All versions | No fix listed |
| emc vnxe oe firmware | All versions | No fix listed |
References
- 20160919 ESA-2016-096: EMC Celerra, VNX1, VNX2 and VNXe SMB NTLM Authentication Weak Nonce Vulnerability mailing-list third-party-advisory
- www.securityfocus.com
- 93023 vdb-entry
- 1036843 vdb-entry