CVE-2017-5570 An issue was discovered in eClinicalWorks Patient Portal 7.0 build 13. This is a blind SQL injection within the messageJson.jsp, which can only be exploited by authenticated users via an HTTP POST req...
HighCVSS 8.8
EPSS 1.2%
- Published
- Updated
- Exploit status
- No public exploit known
Description
An issue was discovered in eClinicalWorks Patient Portal 7.0 build 13. This is a blind SQL injection within the messageJson.jsp, which can only be exploited by authenticated users via an HTTP POST request and which can be used to dump database data out to a malicious server, using an out-of-band technique such as select_loadfile().
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| eclinicalworks patient portal | = 7.0 | No fix listed |
References
- 95742 third-party-advisory vdb-entry
- gist.github.com third-party-advisory