Skip to content

CVE-2017-5671 Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x before 10.12.013309 have /usr/bin/lua installed setuid to the itadmin account, which...

HighCVSS 8.8 EPSS 1.4% Public exploit
Published
Updated
Exploit status
Public exploit available

Description

Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x before 10.12.013309 have /usr/bin/lua installed setuid to the itadmin account, which allows local users to conduct a BusyBox jailbreak attack and obtain root privileges by overwriting the /etc/shadow file.

Upgrade path

7 packages: 7 fixed.

PackageAffectedFixed inStatus
honeywell intermec pc23 firmware <= 10.10.011406 after 10.10.011406 Fixed
honeywell intermec pc42 firmware <= 10.10.011406 after 10.10.011406 Fixed
honeywell intermec pc43 firmware <= 10.10.011406 after 10.10.011406 Fixed
honeywell intermec pd43 firmware <= 10.10.011406 after 10.10.011406 Fixed
honeywell intermec pm23 firmware <= 10.10.011406 after 10.10.011406 Fixed
honeywell intermec pm42 firmware <= 10.10.011406 after 10.10.011406 Fixed
honeywell intermec pm43 firmware <= 10.10.011406 after 10.10.011406 Fixed

Affected products

ProductAffected versionsFixed in
honeywell intermec pc23 firmware <= 10.10.011406 No fix listed
honeywell intermec pc42 firmware <= 10.10.011406 No fix listed
honeywell intermec pc43 firmware <= 10.10.011406 No fix listed
honeywell intermec pd43 firmware <= 10.10.011406 No fix listed
honeywell intermec pm23 firmware <= 10.10.011406 No fix listed
honeywell intermec pm42 firmware <= 10.10.011406 No fix listed
honeywell intermec pm43 firmware <= 10.10.011406 No fix listed

References