A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Upgrade path
6 packages: 3 fixed, 2 with no fix yet.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Siemens sinumerik 808d v4.7 firmware | All versions | No fix listed | No fix yet |
| Siemens sinumerik 808d v4.8 firmware | All versions | No fix listed | No fix yet |
| Siemens sinumerik 828d v4.7 firmware | <= 4.7 | after 4.7 | Fixed |
| Siemens sinumerik 840d sl v4.7 firmware | <= 4.7 | after 4.7 | Fixed |
| Siemens sinumerik 840d sl v4.8 firmware | <= 4.8 | after 4.8 | Fixed |
| Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 | = SINUMERIK 808D V4.7 : All versions; = SINUMERIK 808D V4.8 : All versions; = SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; = SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5 +1 more | No fix listed | Versions listed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens sinumerik 808d v4.7 firmware | All versions | No fix listed |
| Siemens sinumerik 808d v4.8 firmware | All versions | No fix listed |
| Siemens sinumerik 828d v4.7 firmware | <= 4.7 | No fix listed |
| Siemens sinumerik 840d sl v4.7 firmware | <= 4.7 | No fix listed |
| Siemens sinumerik 840d sl v4.8 firmware | <= 4.8 | No fix listed |
| Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 | = SINUMERIK 808D V4.7 : All versions | No fix listed |
| Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 | = SINUMERIK 808D V4.8 : All versions | No fix listed |
| Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 | = SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1 | No fix listed |
| Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 | = SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5 | No fix listed |
| Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 | = SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3 | No fix listed |