Skip to content

CVE-2018-17176 A replay issue was discovered on Neato Botvac Connected 2.2.0 devices. Manual control mode requires authentication, but once recorded, the authentication (always transmitted in cleartext) can be repla...

HighCVSS 7.5 EPSS 1.0%
Published
Updated
Exploit status
No public exploit known

Description

A replay issue was discovered on Neato Botvac Connected 2.2.0 devices. Manual control mode requires authentication, but once recorded, the authentication (always transmitted in cleartext) can be replayed to /bin/webserver on port 8081. There are no nonces, and timestamps are not checked at all.

Affected products

ProductAffected versionsFixed in
neatorobotics botvac d4 connected firmware = 2.2.0 No fix listed
neatorobotics botvac d6 connected firmware = 2.2.0 No fix listed
neatorobotics botvac d7 connected firmware = 2.2.0 No fix listed

References