Skip to content

CVE-2018-17916 InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a....

CriticalCVSS 9.8 EPSS 3.7%
Published
Updated
Exploit status
No public exploit known

Description

InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. If InduSoft Web Studio remote communication security was not enabled, or a password was left blank, a remote user could send a carefully crafted packet to invoke an arbitrary process, with potential for code to be executed. The code would be executed under the privileges of the InduSoft Web Studio or InTouch Edge HMI runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Edge HMI server machine.

Affected products

ProductAffected versionsFixed in
AVEVA indusoft web studio = 6.1-sp5 No fix listed
AVEVA indusoft web studio = 6.1-sp6_p3 No fix listed
AVEVA indusoft web studio = 7.1 No fix listed
AVEVA indusoft web studio = 7.1-sp1 No fix listed
AVEVA indusoft web studio = 7.1-sp2 No fix listed
AVEVA indusoft web studio = 7.1-sp3 No fix listed
AVEVA indusoft web studio = 7.1-sp3_p1 No fix listed
AVEVA indusoft web studio = 7.1-sp3_p2 No fix listed
AVEVA indusoft web studio = 7.1-sp3_p3 No fix listed
AVEVA indusoft web studio = 7.1-sp3_p4 No fix listed
AVEVA indusoft web studio = 7.1-sp3_p5 No fix listed
AVEVA indusoft web studio = 7.1-sp3_p6 No fix listed
AVEVA indusoft web studio = 7.1-sp3_p7 No fix listed
AVEVA indusoft web studio = 7.1-sp3_p8 No fix listed
AVEVA indusoft web studio = 7.1-sp3_p9 No fix listed
AVEVA indusoft web studio = 8.0 No fix listed
AVEVA indusoft web studio = 8.0-p1 No fix listed
AVEVA indusoft web studio = 8.0-p2 No fix listed
AVEVA indusoft web studio = 8.0-p3 No fix listed
AVEVA indusoft web studio = 8.0-sp1 No fix listed
AVEVA indusoft web studio = 8.0-sp1_p1 No fix listed
AVEVA indusoft web studio = 8.0-sp2 No fix listed
AVEVA indusoft web studio = 8.0-sp2_p1 No fix listed
AVEVA indusoft web studio = 8.1 No fix listed
AVEVA indusoft web studio = 8.1-p1 No fix listed
Show 5 more
ProductAffected versionsFixed in
AVEVA indusoft web studio = 8.1-sp1 No fix listed
AVEVA indusoft web studio = 8.1-sp1_p1 No fix listed
AVEVA edge = 8.1 No fix listed
AVEVA edge = 8.1-sp1 No fix listed
AVEVA intouch machine edition 2014 = r2 No fix listed