Skip to content

CVE-2018-6011 The time-based one-time-password (TOTP) function in the application logic of the Green Electronics RainMachine Mini-8 (2nd generation) uses the administrator's password hash to generate a 6-digit temp...

HighCVSS 8.1 EPSS 1.1%
Published
Updated
Exploit status
No public exploit known

Description

The time-based one-time-password (TOTP) function in the application logic of the Green Electronics RainMachine Mini-8 (2nd generation) uses the administrator's password hash to generate a 6-digit temporary passcode that can be used for remote and local access, aka a "Use of Password Hash Instead of Password for Authentication" issue. This is exploitable by an attacker who discovers a hash value in the rainmachine-settings.sqlite file.

Affected products

ProductAffected versionsFixed in
rainmachine mini-8 firmware >= 4.0.539, <= 4.0.975 No fix listed