CVE-2018-9077 Iomega and LenovoEMC NAS Web UI Vulnerabilities

HighCVSS 8.1 EPSS 1.6%
Published
Updated
Exploit status
No public exploit known

Description

For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, when changing the name of a share, an attacker can craft a command injection payload using backtick "``" characters in the share : name parameter. As a result, arbitrary commands may be executed as the root user. The attack requires a value __c and iomega parameter.

Upgrade path

4 packages: 4 fixed.

PackageAffectedFixed inStatus
Lenovo Group Ltd. EZ Media and Backup Center >= 4.1.402.34662, <= 4.1.402.34662 after 4.1.402.34662 Fixed
Lenovo Group Ltd. Iomega StorCenter >= 4.1.402.34662, <= 4.1.402.34662 after 4.1.402.34662 Fixed
Lenovo Group Ltd. LenovoEMC >= 4.1.402.34662, <= 4.1.402.34662 after 4.1.402.34662 Fixed
lenovoemc firmware <= 4.1.402.34662 after 4.1.402.34662 Fixed

Affected products

ProductAffected versionsFixed in
lenovoemc firmware <= 4.1.402.34662 No fix listed
Lenovo Group Ltd. Iomega StorCenter >= 4.1.402.34662, <= 4.1.402.34662 No fix listed
Lenovo Group Ltd. LenovoEMC >= 4.1.402.34662, <= 4.1.402.34662 No fix listed
Lenovo Group Ltd. EZ Media and Backup Center >= 4.1.402.34662, <= 4.1.402.34662 No fix listed