Skip to content

CVE-2019-12257 Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the DHCP client component. There is an IPNET security vulnerability: Heap overflow in DHCP Offer/ACK parsing inside ipdhcpc.

HighCVSS 8.8 EPSS 84.3%
Published
Updated
Exploit status
No public exploit known
Technology
Network Appliances

Description

Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the DHCP client component. There is an IPNET security vulnerability: Heap overflow in DHCP Offer/ACK parsing inside ipdhcpc.

Upgrade path

10 packages: 10 fixed.

PackageAffectedFixed inStatus
Belden garrettcom magnum dx940e firmware <= 1.0.1_y7 after 1.0.1_y7 Fixed
Belden hirschmann hios <= 05.3.06; <= 07.0.07; <= 07.2.04; <= 07.5.01 after 05.3.06, 07.0.07, 07.2.04, 07.5.01 Fixed
netapp e-series santricity os controller >= 8.00, <= 8.40.50.00 after 8.40.50.00 Fixed
Siemens ruggedcom win7000 firmware < bs5.2.461.17 bs5.2.461.17 Fixed
Siemens ruggedcom win7018 firmware < bs5.2.461.17 bs5.2.461.17 Fixed
Siemens ruggedcom win7025 firmware < bs5.2.461.17 bs5.2.461.17 Fixed
Siemens ruggedcom win7200 firmware < bs5.2.461.17 bs5.2.461.17 Fixed
Siemens siprotec 5 firmware < 7.59; < 7.91 7.59, 7.91 Fixed
SonicWall SonicOS = 6.2.7.0; = 6.2.7.1; = 6.2.7.7; >= 5.9.0.0, <= 5.9.0.7 +12 more after 5.9.0.7, 5.9.1.12, 6.2.3.1, 6.2.4.3, 6.2.5.3, 6.2.6.1, 6.2.7.4, 6.2.9.2, 6.5.0.3, 6.5.1.4, 6.5.2.3, 6.5.3.3, 6.5.4.3 Fixed
windriver vxworks >= 6.5, < 6.9.4 6.9.4 Fixed

Affected products

ProductAffected versionsFixed in
windriver vxworks >= 6.5, < 6.9.4 6.9.4
SonicWall SonicOS >= 5.9.0.0, <= 5.9.0.7 No fix listed
SonicWall SonicOS >= 5.9.1.0., <= 5.9.1.12 No fix listed
SonicWall SonicOS >= 6.2.0.0, <= 6.2.3.1 No fix listed
SonicWall SonicOS >= 6.2.4.0, <= 6.2.4.3 No fix listed
SonicWall SonicOS >= 6.2.5.0, <= 6.2.5.3 No fix listed
SonicWall SonicOS >= 6.2.6.0, <= 6.2.6.1 No fix listed
SonicWall SonicOS >= 6.2.7.0, <= 6.2.7.4 No fix listed
SonicWall SonicOS >= 6.2.9.0, <= 6.2.9.2 No fix listed
SonicWall SonicOS >= 6.5.0.0, <= 6.5.0.3 No fix listed
SonicWall SonicOS >= 6.5.1.0, <= 6.5.1.4 No fix listed
SonicWall SonicOS >= 6.5.2.0, <= 6.5.2.3 No fix listed
SonicWall SonicOS >= 6.5.3.0, <= 6.5.3.3 No fix listed
SonicWall SonicOS >= 6.5.4.0., <= 6.5.4.3 No fix listed
SonicWall SonicOS = 6.2.7.0 No fix listed
SonicWall SonicOS = 6.2.7.1 No fix listed
SonicWall SonicOS = 6.2.7.7 No fix listed
Siemens siprotec 5 firmware < 7.59 7.59
Siemens siprotec 5 firmware < 7.91 7.91
netapp e-series santricity os controller >= 8.00, <= 8.40.50.00 No fix listed
Siemens ruggedcom win7000 firmware < bs5.2.461.17 bs5.2.461.17
Siemens ruggedcom win7018 firmware < bs5.2.461.17 bs5.2.461.17
Siemens ruggedcom win7025 firmware < bs5.2.461.17 bs5.2.461.17
Siemens ruggedcom win7200 firmware < bs5.2.461.17 bs5.2.461.17
Belden hirschmann hios <= 07.0.07 No fix listed
Show 4 more
ProductAffected versionsFixed in
Belden hirschmann hios <= 07.5.01 No fix listed
Belden hirschmann hios <= 07.2.04 No fix listed
Belden hirschmann hios <= 05.3.06 No fix listed
Belden garrettcom magnum dx940e firmware <= 1.0.1_y7 No fix listed

References