Skip to content

CVE-2019-12310 ExaGrid appliances with firmware version v4.8.1.1044.P50 have a /monitor/data/Upgrade/ directory traversal vulnerability, which allows remote attackers to view and retrieve verbose logging information...

CriticalCVSS 9.8 EPSS 3.3%
Published
Updated
Exploit status
No public exploit known

Description

ExaGrid appliances with firmware version v4.8.1.1044.P50 have a /monitor/data/Upgrade/ directory traversal vulnerability, which allows remote attackers to view and retrieve verbose logging information. Files within this directory were observed to contain sensitive run-time information, including Base64 encoded 'support' credentials, leading to administrative access of the device.

Upgrade path

1 package: 0 fixed.

PackageAffectedFixed inStatus
exagrid backup appliance firmware = 48.1.1044.p50 No fix listed Versions listed

Affected products

ProductAffected versionsFixed in
exagrid backup appliance firmware = 48.1.1044.p50 No fix listed

References