CVE-2020-10270 RVD#2557: Hardcoded Credentials on MiRX00 Control Dashboard
- Published
- Updated
- Exploit status
- No public exploit known
Description
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.
Upgrade path
11 packages: 10 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| aliasrobotics mir100 firmware | <= 2.8.1.1 | after 2.8.1.1 | Fixed |
| aliasrobotics mir1000 firmware | <= 2.8.1.1 | after 2.8.1.1 | Fixed |
| aliasrobotics mir200 firmware | <= 2.8.1.1 | after 2.8.1.1 | Fixed |
| aliasrobotics mir250 firmware | <= 2.8.1.1 | after 2.8.1.1 | Fixed |
| aliasrobotics mir500 firmware | <= 2.8.1.1 | after 2.8.1.1 | Fixed |
| enabled-robotics er-flex firmware | <= 2.8.1.1 | after 2.8.1.1 | Fixed |
| enabled-robotics er-lite firmware | <= 2.8.1.1 | after 2.8.1.1 | Fixed |
| enabled-robotics er-one firmware | <= 2.8.1.1 | after 2.8.1.1 | Fixed |
| mobile-industrial-robotics er200 firmware | <= 2.8.1.1 | after 2.8.1.1 | Fixed |
| uvd-robots uvd robots firmware | <= 2.8.1.1 | after 2.8.1.1 | Fixed |
| Mobile Industrial Robots A/S MiR100 | = v2.8.1.1 and before | No fix listed | Versions listed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| aliasrobotics mir100 firmware | <= 2.8.1.1 | No fix listed |
| aliasrobotics mir200 firmware | <= 2.8.1.1 | No fix listed |
| aliasrobotics mir250 firmware | <= 2.8.1.1 | No fix listed |
| aliasrobotics mir500 firmware | <= 2.8.1.1 | No fix listed |
| aliasrobotics mir1000 firmware | <= 2.8.1.1 | No fix listed |
| mobile-industrial-robotics er200 firmware | <= 2.8.1.1 | No fix listed |
| enabled-robotics er-lite firmware | <= 2.8.1.1 | No fix listed |
| enabled-robotics er-flex firmware | <= 2.8.1.1 | No fix listed |
| enabled-robotics er-one firmware | <= 2.8.1.1 | No fix listed |
| uvd-robots uvd robots firmware | <= 2.8.1.1 | No fix listed |
| Mobile Industrial Robots A/S MiR100 | = v2.8.1.1 and before | No fix listed |
References
- github.com exploit third-party-advisory