Skip to content

CVE-2020-25182 Rockwell Automation ISaGRAF5 Runtime Uncontrolled Search Path Element

MediumCVSS 6.7 EPSS 0.45%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
No known exploitation · automatable: no · technical impact: total
Technology
Windows

Description

Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.

Upgrade path

18 packages: 10 fixed, 5 with no fix yet.

PackageAffectedFixed inStatus
rockwellautomation micro810 firmware All versions No fix listed No fix yet
rockwellautomation micro820 firmware All versions No fix listed No fix yet
rockwellautomation micro830 firmware All versions No fix listed No fix yet
rockwellautomation micro850 firmware All versions No fix listed No fix yet
rockwellautomation micro870 firmware All versions No fix listed No fix yet
rockwellautomation aadvance controller <= 1.40 after 1.40 Fixed
rockwellautomation isagraf free runtime <= 6.6.8 after 6.6.8 Fixed
rockwellautomation isagraf runtime >= 5.0, < 6.0 6.0 Fixed
schneider-electric easergy c5 firmware < 1.1.0 1.1.0 Fixed
schneider-electric easergy t300 firmware <= 2.7.1 after 2.7.1 Fixed
schneider-electric micom c264 firmware < d6.1 d6.1 Fixed
schneider-electric saitel dp firmware <= 11.06.21 after 11.06.21 Fixed
schneider-electric saitel dr firmware <= 11.06.12 after 11.06.12 Fixed
schneider-electric scd2200 firmware <= 10024 after 10024 Fixed
xylem multismart firmware < 3.2.0 3.2.0 Fixed
Rockwell Automation ISaGRAF Runtime = 4.x; = 5.x No fix listed Versions listed
schneider-electric epas gtw firmware = 6.4 No fix listed Versions listed
schneider-electric pacis gtw firmware = 5.1; = 5.2; = 6.1; = 6.3 No fix listed Versions listed

Affected products

ProductAffected versionsFixed in
schneider-electric easergy t300 firmware <= 2.7.1 No fix listed
schneider-electric easergy c5 firmware < 1.1.0 1.1.0
schneider-electric micom c264 firmware < d6.1 d6.1
schneider-electric pacis gtw firmware = 5.1 No fix listed
schneider-electric pacis gtw firmware = 5.2 No fix listed
schneider-electric pacis gtw firmware = 6.1 No fix listed
schneider-electric pacis gtw firmware = 6.3 No fix listed
schneider-electric saitel dp firmware <= 11.06.21 No fix listed
schneider-electric epas gtw firmware = 6.4 No fix listed
schneider-electric saitel dr firmware <= 11.06.12 No fix listed
schneider-electric scd2200 firmware <= 10024 No fix listed
rockwellautomation aadvance controller <= 1.40 No fix listed
rockwellautomation isagraf free runtime <= 6.6.8 No fix listed
rockwellautomation micro810 firmware All versions No fix listed
rockwellautomation micro820 firmware All versions No fix listed
rockwellautomation micro830 firmware All versions No fix listed
rockwellautomation micro850 firmware All versions No fix listed
rockwellautomation micro870 firmware All versions No fix listed
xylem multismart firmware < 3.2.0 3.2.0
rockwellautomation isagraf runtime >= 5.0, < 6.0 6.0
Rockwell Automation ISaGRAF Runtime = 4.x No fix listed
Rockwell Automation ISaGRAF Runtime = 5.x No fix listed

References