Skip to content

CVE-2021-22707 A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4....

CriticalCVSS 9.8 EPSS 64.6% Scanner template
Published
Updated
Exploit status
No public exploit known

Description

A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.

Upgrade path

6 packages: 6 fixed.

PackageAffectedFixed inStatus
schneider-electric evlink city evc1s22p4 firmware < r8_v3.4.0.1 r8_v3.4.0.1 Fixed
schneider-electric evlink city evc1s7p4 firmware < r8_v3.4.0.1 r8_v3.4.0.1 Fixed
schneider-electric evlink parking ev.2 firmware < r8_v3.4.0.1 r8_v3.4.0.1 Fixed
schneider-electric evlink parking evf2 firmware < r8_v3.4.0.1 r8_v3.4.0.1 Fixed
schneider-electric evlink parking evw2 firmware < r8_v3.4.0.1 r8_v3.4.0.1 Fixed
schneider-electric evlink smart wallbox evb1a firmware < r8_v3.4.0.1 r8_v3.4.0.1 Fixed

Affected products

ProductAffected versionsFixed in
schneider-electric evlink city evc1s22p4 firmware < r8_v3.4.0.1 r8_v3.4.0.1
schneider-electric evlink city evc1s7p4 firmware < r8_v3.4.0.1 r8_v3.4.0.1
schneider-electric evlink parking evw2 firmware < r8_v3.4.0.1 r8_v3.4.0.1
schneider-electric evlink parking evf2 firmware < r8_v3.4.0.1 r8_v3.4.0.1
schneider-electric evlink parking ev.2 firmware < r8_v3.4.0.1 r8_v3.4.0.1
schneider-electric evlink smart wallbox evb1a firmware < r8_v3.4.0.1 r8_v3.4.0.1

References