CVE-2021-25663 A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3....
- Published
- Updated
- Exploit status
- No public exploit known
Description
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values.
Upgrade path
8 packages: 4 fixed, 4 with no fix yet.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Siemens Capital Embedded AR Classic 431-422 | All versions | No fix listed | No fix yet |
| Siemens capital vstar | All versions | No fix listed | No fix yet |
| Siemens nucleus net | = All versions; All versions | No fix listed | No fix yet |
| Siemens Nucleus Source Code | All versions | No fix listed | No fix yet |
| Siemens Capital Embedded AR Classic R20-11 | < V2303 | V2303 | Fixed |
| Siemens nucleus readystart | < 4.1.0; < 2017.02.4 | 4.1.0, 2017.02.4 | Fixed |
| Siemens nucleus readystart v3 | < V2017.02.4 | V2017.02.4 | Fixed |
| Siemens nucleus readystart v4 | < V4.1.0 | V4.1.0 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens capital vstar | All versions | No fix listed |
| Siemens nucleus net | All versions | No fix listed |
| Siemens nucleus readystart | < 4.1.0 | 4.1.0 |
| Siemens nucleus readystart | < 2017.02.4 | 2017.02.4 |
| Siemens Nucleus Source Code | All versions | No fix listed |
| Siemens Capital Embedded AR Classic 431-422 | All versions | No fix listed |
| Siemens Capital Embedded AR Classic R20-11 | < V2303 | V2303 |
| Siemens nucleus net | = All versions | No fix listed |
| Siemens nucleus readystart v3 | < V2017.02.4 | V2017.02.4 |
| Siemens nucleus readystart v4 | < V4.1.0 | V4.1.0 |
References
- cert-portal.siemens.com
- cert-portal.siemens.com vendor-advisory
- us-cert.cisa.gov third-party-advisory us-government-resource