CVE-2021-29242 CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or...
HighCVSS 7.3
EPSS 1.3%
- Published
- Updated
- Exploit status
- No public exploit known
Description
CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages.
Upgrade path
22 packages: 22 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| CODESYS Control for BeagleBone SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 | Fixed |
| CODESYS Control for emPC-A/iMX6 SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 | Fixed |
| CODESYS Control for IOT2000 SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 | Fixed |
| CODESYS Control for Linux ARM SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 | Fixed |
| CODESYS Control for Linux SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 | Fixed |
| CODESYS Control for PFC100 SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 | Fixed |
| CODESYS Control for PFC200 SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 | Fixed |
| CODESYS Control for PLCnext SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 | Fixed |
| CODESYS Control for Raspberry Pi SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 | Fixed |
| CODESYS Control for WAGO Touch Panels 600 SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 | Fixed |
| CODESYS control rte | >= 3.0, < 3.5.17.0 | 3.5.17.0 | Fixed |
| CODESYS control runtime system toolkit | >= 3.0, < 3.5.17.0 | 3.5.17.0 | Fixed |
| CODESYS control win | >= 3.0, < 3.5.17.0 | 3.5.17.0 | Fixed |
| CODESYS edge gateway | >= 3.0, < 3.5.17.0; >= 3.0, < 4.1.0.0 | 3.5.17.0, 4.1.0.0 | Fixed |
| CODESYS embedded target visu toolkit | >= 3.0, < 3.5.17.0 | 3.5.17.0 | Fixed |
| CODESYS Gateway | >= 3.0, < 3.5.17.0 | 3.5.17.0 | Fixed |
| CODESYS hmi | >= 3.0, < 3.5.17.0 | 3.5.17.0 | Fixed |
| CODESYS opc server | >= 3.0, < 3.5.17.0 | 3.5.17.0 | Fixed |
| CODESYS PLCHandler | >= 3.0, < 3.5.17.0 | 3.5.17.0 | Fixed |
| CODESYS remote target visu toolkit | >= 3.0, < 3.5.17.0 | 3.5.17.0 | Fixed |
| CODESYS safety sil | >= 3.0, < 3.5.17.0 | 3.5.17.0 | Fixed |
| CODESYS simulation runtime | >= 3.0, < 3.5.17.0 | 3.5.17.0 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| CODESYS Control for BeagleBone SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 |
| CODESYS Control for emPC-A/iMX6 SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 |
| CODESYS Control for IOT2000 SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 |
| CODESYS Control for Linux ARM SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 |
| CODESYS Control for Linux SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 |
| CODESYS Control for PFC100 SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 |
| CODESYS Control for PFC200 SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 |
| CODESYS Control for PLCnext SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 |
| CODESYS Control for Raspberry Pi SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 |
| CODESYS Control for WAGO Touch Panels 600 SL | >= 3.0, < 4.1.0.0 | 4.1.0.0 |
| CODESYS control rte | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
| CODESYS control runtime system toolkit | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
| CODESYS control win | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
| CODESYS edge gateway | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
| CODESYS edge gateway | >= 3.0, < 4.1.0.0 | 4.1.0.0 |
| CODESYS embedded target visu toolkit | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
| CODESYS Gateway | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
| CODESYS hmi | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
| CODESYS opc server | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
| CODESYS PLCHandler | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
| CODESYS remote target visu toolkit | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
| CODESYS safety sil | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
| CODESYS simulation runtime | >= 3.0, < 3.5.17.0 | 3.5.17.0 |
References
- customers.codesys.com permissions-required vendor-advisory
- customers.codesys.com vendor-advisory
- www.codesys.com vendor-advisory