Skip to content

CVE-2021-29242 CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or...

HighCVSS 7.3 EPSS 1.3%
Published
Updated
Exploit status
No public exploit known

Description

CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages.

Upgrade path

22 packages: 22 fixed.

PackageAffectedFixed inStatus
CODESYS Control for BeagleBone SL >= 3.0, < 4.1.0.0 4.1.0.0 Fixed
CODESYS Control for emPC-A/iMX6 SL >= 3.0, < 4.1.0.0 4.1.0.0 Fixed
CODESYS Control for IOT2000 SL >= 3.0, < 4.1.0.0 4.1.0.0 Fixed
CODESYS Control for Linux ARM SL >= 3.0, < 4.1.0.0 4.1.0.0 Fixed
CODESYS Control for Linux SL >= 3.0, < 4.1.0.0 4.1.0.0 Fixed
CODESYS Control for PFC100 SL >= 3.0, < 4.1.0.0 4.1.0.0 Fixed
CODESYS Control for PFC200 SL >= 3.0, < 4.1.0.0 4.1.0.0 Fixed
CODESYS Control for PLCnext SL >= 3.0, < 4.1.0.0 4.1.0.0 Fixed
CODESYS Control for Raspberry Pi SL >= 3.0, < 4.1.0.0 4.1.0.0 Fixed
CODESYS Control for WAGO Touch Panels 600 SL >= 3.0, < 4.1.0.0 4.1.0.0 Fixed
CODESYS control rte >= 3.0, < 3.5.17.0 3.5.17.0 Fixed
CODESYS control runtime system toolkit >= 3.0, < 3.5.17.0 3.5.17.0 Fixed
CODESYS control win >= 3.0, < 3.5.17.0 3.5.17.0 Fixed
CODESYS edge gateway >= 3.0, < 3.5.17.0; >= 3.0, < 4.1.0.0 3.5.17.0, 4.1.0.0 Fixed
CODESYS embedded target visu toolkit >= 3.0, < 3.5.17.0 3.5.17.0 Fixed
CODESYS Gateway >= 3.0, < 3.5.17.0 3.5.17.0 Fixed
CODESYS hmi >= 3.0, < 3.5.17.0 3.5.17.0 Fixed
CODESYS opc server >= 3.0, < 3.5.17.0 3.5.17.0 Fixed
CODESYS PLCHandler >= 3.0, < 3.5.17.0 3.5.17.0 Fixed
CODESYS remote target visu toolkit >= 3.0, < 3.5.17.0 3.5.17.0 Fixed
CODESYS safety sil >= 3.0, < 3.5.17.0 3.5.17.0 Fixed
CODESYS simulation runtime >= 3.0, < 3.5.17.0 3.5.17.0 Fixed

Affected products

ProductAffected versionsFixed in
CODESYS Control for BeagleBone SL >= 3.0, < 4.1.0.0 4.1.0.0
CODESYS Control for emPC-A/iMX6 SL >= 3.0, < 4.1.0.0 4.1.0.0
CODESYS Control for IOT2000 SL >= 3.0, < 4.1.0.0 4.1.0.0
CODESYS Control for Linux ARM SL >= 3.0, < 4.1.0.0 4.1.0.0
CODESYS Control for Linux SL >= 3.0, < 4.1.0.0 4.1.0.0
CODESYS Control for PFC100 SL >= 3.0, < 4.1.0.0 4.1.0.0
CODESYS Control for PFC200 SL >= 3.0, < 4.1.0.0 4.1.0.0
CODESYS Control for PLCnext SL >= 3.0, < 4.1.0.0 4.1.0.0
CODESYS Control for Raspberry Pi SL >= 3.0, < 4.1.0.0 4.1.0.0
CODESYS Control for WAGO Touch Panels 600 SL >= 3.0, < 4.1.0.0 4.1.0.0
CODESYS control rte >= 3.0, < 3.5.17.0 3.5.17.0
CODESYS control runtime system toolkit >= 3.0, < 3.5.17.0 3.5.17.0
CODESYS control win >= 3.0, < 3.5.17.0 3.5.17.0
CODESYS edge gateway >= 3.0, < 3.5.17.0 3.5.17.0
CODESYS edge gateway >= 3.0, < 4.1.0.0 4.1.0.0
CODESYS embedded target visu toolkit >= 3.0, < 3.5.17.0 3.5.17.0
CODESYS Gateway >= 3.0, < 3.5.17.0 3.5.17.0
CODESYS hmi >= 3.0, < 3.5.17.0 3.5.17.0
CODESYS opc server >= 3.0, < 3.5.17.0 3.5.17.0
CODESYS PLCHandler >= 3.0, < 3.5.17.0 3.5.17.0
CODESYS remote target visu toolkit >= 3.0, < 3.5.17.0 3.5.17.0
CODESYS safety sil >= 3.0, < 3.5.17.0 3.5.17.0
CODESYS simulation runtime >= 3.0, < 3.5.17.0 3.5.17.0

References