CVE-2021-43522 An issue was discovered in Insyde InsydeH2O with kernel 5.1 through 2021-11-08, 5.2 through 2021-11-08, and 5.3 through 2021-11-08. A StorageSecurityCommandDxe SMM memory corruption vulnerability allo...
HighCVSS 7.5
EPSS 0.26%
- Published
- Updated
- Exploit status
- No public exploit known
Description
An issue was discovered in Insyde InsydeH2O with kernel 5.1 through 2021-11-08, 5.2 through 2021-11-08, and 5.3 through 2021-11-08. A StorageSecurityCommandDxe SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Upgrade path
19 packages: 19 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| insydeh2o | >= 5.1, < 5.14.34; >= 5.2, < 5.24.34; >= 5.3, < 5.33.34 | 5.14.34, 5.24.34, 5.33.34 | Fixed |
| Siemens RUGGEDCOM APE1808 - BIOS | < V1.0.202N | V1.0.202N | Fixed |
| Siemens SIMATIC Field PG M5 | < V22.01.10 | V22.01.10 | Fixed |
| Siemens SIMATIC Field PG M6 | < V26.01.13 | V26.01.13 | Fixed |
| Siemens SIMATIC IPC127E | < V27.01.09 | V27.01.09 | Fixed |
| Siemens SIMATIC IPC227G | < V28.01.04 | V28.01.04 | Fixed |
| Siemens SIMATIC IPC277G | < V28.01.04 | V28.01.04 | Fixed |
| Siemens SIMATIC IPC327G | < V28.01.04 | V28.01.04 | Fixed |
| Siemens SIMATIC IPC377G | < V28.01.04 | V28.01.04 | Fixed |
| Siemens SIMATIC IPC427E | < V21.01.17 | V21.01.17 | Fixed |
| Siemens SIMATIC IPC477E | < V21.01.17 | V21.01.17 | Fixed |
| Siemens SIMATIC IPC477E PRO | < V21.01.17 | V21.01.17 | Fixed |
| Siemens SIMATIC IPC627E | < V25.02.12 | V25.02.12 | Fixed |
| Siemens SIMATIC IPC647E | < V25.02.12 | V25.02.12 | Fixed |
| Siemens SIMATIC IPC677E | < V25.02.12 | V25.02.12 | Fixed |
| Siemens SIMATIC IPC847E | < V25.02.12 | V25.02.12 | Fixed |
| Siemens SIMATIC ITP1000 | < V23.01.10 | V23.01.10 | Fixed |
| Siemens SIMATIC IPC277G PRO | < V28.01.04 | V28.01.04 | Fixed |
| Siemens SIPLUS IPC427E | < V21.01.17 | V21.01.17 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens RUGGEDCOM APE1808 - BIOS | < V1.0.202N | V1.0.202N |
| Siemens SIMATIC Field PG M5 | < V22.01.10 | V22.01.10 |
| Siemens SIMATIC Field PG M6 | < V26.01.13 | V26.01.13 |
| Siemens SIMATIC IPC127E | < V27.01.09 | V27.01.09 |
| Siemens SIMATIC IPC227G | < V28.01.04 | V28.01.04 |
| Siemens SIMATIC IPC277G | < V28.01.04 | V28.01.04 |
| Siemens SIMATIC IPC277G PRO | < V28.01.04 | V28.01.04 |
| Siemens SIMATIC IPC327G | < V28.01.04 | V28.01.04 |
| Siemens SIMATIC IPC377G | < V28.01.04 | V28.01.04 |
| Siemens SIMATIC IPC427E | < V21.01.17 | V21.01.17 |
| Siemens SIMATIC IPC477E | < V21.01.17 | V21.01.17 |
| Siemens SIMATIC IPC477E PRO | < V21.01.17 | V21.01.17 |
| Siemens SIMATIC IPC627E | < V25.02.12 | V25.02.12 |
| Siemens SIMATIC IPC647E | < V25.02.12 | V25.02.12 |
| Siemens SIMATIC IPC677E | < V25.02.12 | V25.02.12 |
| Siemens SIMATIC IPC847E | < V25.02.12 | V25.02.12 |
| Siemens SIMATIC ITP1000 | < V23.01.10 | V23.01.10 |
| Siemens SIPLUS IPC427E | < V21.01.17 | V21.01.17 |
| insydeh2o | >= 5.1, < 5.14.34 | 5.14.34 |
| insydeh2o | >= 5.2, < 5.24.34 | 5.24.34 |
| insydeh2o | >= 5.3, < 5.33.34 | 5.33.34 |
References
- www.insyde.com vendor-advisory
- security.netapp.com third-party-advisory
- cert-portal.siemens.com third-party-advisory
- www.kb.cert.org
- cert-portal.siemens.com
- ENISA EUVD EUVD-2021-30451 third-party-advisory