CVE-2021-45034 A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All ve...
HighCVSS 7.5
EPSS 2.4%
- Published
- Updated
- Exploit status
- No public exploit known
Description
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links.
Upgrade path
8 packages: 4 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Siemens cp-8000 master module with io -25+70 firmware | < 16.20 | 16.20 | Fixed |
| Siemens cp-8000 master module with io -40+70 firmware | < 16.20 | 16.20 | Fixed |
| Siemens cp-8021 master module firmware | < 16.20 | 16.20 | Fixed |
| Siemens cp-8022 master module with gprs firmware | < 16.20 | 16.20 | Fixed |
| Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C | = All versions < V16.20 | No fix listed | Versions listed |
| Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C | = All versions < V16.20 | No fix listed | Versions listed |
| Siemens CP-8021 MASTER MODULE | = All versions < V16.20 | No fix listed | Versions listed |
| Siemens CP-8022 MASTER MODULE WITH GPRS | = All versions < V16.20 | No fix listed | Versions listed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens cp-8000 master module with io -25+70 firmware | < 16.20 | 16.20 |
| Siemens cp-8000 master module with io -40+70 firmware | < 16.20 | 16.20 |
| Siemens cp-8021 master module firmware | < 16.20 | 16.20 |
| Siemens cp-8022 master module with gprs firmware | < 16.20 | 16.20 |
| Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C | = All versions < V16.20 | No fix listed |
| Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C | = All versions < V16.20 | No fix listed |
| Siemens CP-8021 MASTER MODULE | = All versions < V16.20 | No fix listed |
| Siemens CP-8022 MASTER MODULE WITH GPRS | = All versions < V16.20 | No fix listed |
References
- packetstormsecurity.com exploit third-party-advisory vdb-entry
- 20220414 SEC Consult SA-20220413 :: Missing Authentication at File Download & Denial of Service in Siemens A8000 PLC exploit mailing-list third-party-advisory
- cert-portal.siemens.com patch vendor-advisory