CVE-2021-45971 An issue was discovered in SdHostDriver in Insyde InsydeH2O with kernel 5.1 before 05.16.25, 5.2 before 05.26.25, 5.3 before 05.35.25, 5.4 before 05.43.25, and 5.5 before 05.51.25. A vulnerability exi...
HighCVSS 8.2
EPSS 0.29%
- Published
- Updated
- Exploit status
- No public exploit known
Description
An issue was discovered in SdHostDriver in Insyde InsydeH2O with kernel 5.1 before 05.16.25, 5.2 before 05.26.25, 5.3 before 05.35.25, 5.4 before 05.43.25, and 5.5 before 05.51.25. A vulnerability exists in the SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer (CommBufferData).
Upgrade path
19 packages: 19 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| insydeh2o | >= 5.1, < 5.16.25; >= 5.2, < 5.26.25; >= 5.3, < 5.35.25; >= 5.4, < 5.43.25 +1 more | 5.16.25, 5.26.25, 5.35.25, 5.43.25, 05.51.25 | Fixed |
| Siemens RUGGEDCOM APE1808 - BIOS | < V1.0.202N | V1.0.202N | Fixed |
| Siemens SIMATIC Field PG M5 | < V22.01.10 | V22.01.10 | Fixed |
| Siemens SIMATIC Field PG M6 | < V26.01.13 | V26.01.13 | Fixed |
| Siemens SIMATIC IPC127E | < V27.01.09 | V27.01.09 | Fixed |
| Siemens SIMATIC IPC227G | < V28.01.04 | V28.01.04 | Fixed |
| Siemens SIMATIC IPC277G | < V28.01.04 | V28.01.04 | Fixed |
| Siemens SIMATIC IPC327G | < V28.01.04 | V28.01.04 | Fixed |
| Siemens SIMATIC IPC377G | < V28.01.04 | V28.01.04 | Fixed |
| Siemens SIMATIC IPC427E | < V21.01.17 | V21.01.17 | Fixed |
| Siemens SIMATIC IPC477E | < V21.01.17 | V21.01.17 | Fixed |
| Siemens SIMATIC IPC477E PRO | < V21.01.17 | V21.01.17 | Fixed |
| Siemens SIMATIC IPC627E | < V25.02.12 | V25.02.12 | Fixed |
| Siemens SIMATIC IPC647E | < V25.02.12 | V25.02.12 | Fixed |
| Siemens SIMATIC IPC677E | < V25.02.12 | V25.02.12 | Fixed |
| Siemens SIMATIC IPC847E | < V25.02.12 | V25.02.12 | Fixed |
| Siemens SIMATIC ITP1000 | < V23.01.10 | V23.01.10 | Fixed |
| Siemens SIMATIC IPC277G PRO | < V28.01.04 | V28.01.04 | Fixed |
| Siemens SIPLUS IPC427E | < V21.01.17 | V21.01.17 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens RUGGEDCOM APE1808 - BIOS | < V1.0.202N | V1.0.202N |
| Siemens SIMATIC Field PG M5 | < V22.01.10 | V22.01.10 |
| Siemens SIMATIC Field PG M6 | < V26.01.13 | V26.01.13 |
| Siemens SIMATIC IPC127E | < V27.01.09 | V27.01.09 |
| Siemens SIMATIC IPC227G | < V28.01.04 | V28.01.04 |
| Siemens SIMATIC IPC277G | < V28.01.04 | V28.01.04 |
| Siemens SIMATIC IPC277G PRO | < V28.01.04 | V28.01.04 |
| Siemens SIMATIC IPC327G | < V28.01.04 | V28.01.04 |
| Siemens SIMATIC IPC377G | < V28.01.04 | V28.01.04 |
| Siemens SIMATIC IPC427E | < V21.01.17 | V21.01.17 |
| Siemens SIMATIC IPC477E | < V21.01.17 | V21.01.17 |
| Siemens SIMATIC IPC477E PRO | < V21.01.17 | V21.01.17 |
| Siemens SIMATIC IPC627E | < V25.02.12 | V25.02.12 |
| Siemens SIMATIC IPC647E | < V25.02.12 | V25.02.12 |
| Siemens SIMATIC IPC677E | < V25.02.12 | V25.02.12 |
| Siemens SIMATIC IPC847E | < V25.02.12 | V25.02.12 |
| Siemens SIMATIC ITP1000 | < V23.01.10 | V23.01.10 |
| Siemens SIPLUS IPC427E | < V21.01.17 | V21.01.17 |
| insydeh2o | >= 5.1, < 5.16.25 | 5.16.25 |
| insydeh2o | >= 5.2, < 5.26.25 | 5.26.25 |
| insydeh2o | >= 5.3, < 5.35.25 | 5.35.25 |
| insydeh2o | >= 5.4, < 5.43.25 | 5.43.25 |
| insydeh2o | >= 5.5, < 05.51.25 | 05.51.25 |
References
- www.insyde.com vendor-advisory
- security.netapp.com third-party-advisory
- cert-portal.siemens.com third-party-advisory
- www.kb.cert.org
- cert-portal.siemens.com
- ENISA EUVD EUVD-2021-32677 third-party-advisory