CVE-2022-25752 A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCAL...
- Published
- Updated
- Exploit status
- No public exploit known
Description
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens SCALANCE X302-7 EEC (230V) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X302-7 EEC (230V, coated) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X302-7 EEC (24V) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X302-7 EEC (24V, coated) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X302-7 EEC (2x 230V) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X302-7 EEC (2x 230V, coated) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X302-7 EEC (2x 24V) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X302-7 EEC (2x 24V, coated) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X304-2FE | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X306-1LD FE | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X307-2 EEC (230V) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X307-2 EEC (230V, coated) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X307-2 EEC (24V) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X307-2 EEC (24V, coated) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X307-2 EEC (2x 230V) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X307-2 EEC (2x 230V, coated) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X307-2 EEC (2x 24V) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X307-2 EEC (2x 24V, coated) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X307-3 | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X307-3LD | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X308-2 | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X308-2LD | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X308-2LH | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X308-2LH+ | = All versions < V4.1.4 | No fix listed |
| Siemens scalance x308-2m | = All versions < V4.1.4 | No fix listed |
Show 50 more
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens SCALANCE X308-2M PoE | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X308-2M TS | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X310 | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X310FE | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X320-1 FE | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X320-1-2LD FE | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE X408-2 | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-12M (230V, ports on front) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-12M (230V, ports on rear) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-12M (24V, ports on front) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-12M (24V, ports on rear) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-12M TS (24V) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M EEC (24V, ports on front) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M EEC (24V, ports on rear) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M PoE (230V, ports on front) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M PoE (230V, ports on rear) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M PoE (24V, ports on front) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M PoE (24V, ports on rear) | = All versions < V4.1.4 | No fix listed |
| Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) | = All versions < V4.1.4 | No fix listed |
| Siemens SIPLUS NET SCALANCE X308-2 | = All versions < V4.1.4 | No fix listed |
| Siemens scalance x302-7eec firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x304-2fe firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x306-1ldfe firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x307-2eec firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x307-3 firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x307-3ld firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x308-2 firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x308-2ld firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x308-2lh firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x308-2lh+ firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x308-2m firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x308-2m poe firmware | All versions | No fix listed |
| Siemens scalance x308-2m ts firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x310 firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x310fe firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x320-1fe firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x320-1-2ldfe firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance x408-2 firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance xr324-4m eec firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance xr324-4m poe firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance xr324-4m poe ts firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance xr324-12m firmware | < 4.1.4 | 4.1.4 |
| Siemens scalance xr324-12m ts firmware | < 4.1.4 | 4.1.4 |
| Siemens siplus net scalance x308-2 firmware | < 4.1.4 | 4.1.4 |
References
- cert-portal.siemens.com mitigation patch vendor-advisory