CVE-2022-29223 Buffer overflow on HUB descriptor in Azure RTOS USBX
CriticalCVSS 9.8
EPSS 1.2%
- Published
- Updated
- Exploit status
- No public exploit known
Description
Azure RTOS USBX is a USB host, device, and on-the-go (OTG) embedded stack. In versions prior to 6.1.10, an attacker can cause a buffer overflow by providing the Azure RTOS USBX host stack a HUB descriptor with bNbPorts set to a value greater than UX_MAX_TT which defaults to 8. For a bNbPorts value of 255, the implementation of ux_host_class_hub_descriptor_get function will modify the contents of hub -> ux_host_class_hub_device -> ux_device_hub_tt array violating the end boundary by 255 - UX_MAX_TT items. The USB host stack needs to validate the number of ports reported by the hub, and if the value is larger than UX_MAX_TT, USB stack needs to reject the request. This fix has been included in USBX release 6.1.10.
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| azure-rtos usbx | = < 6.1.10 | No fix listed |
| eclipse threadx usbx | < 6.1.10 | 6.1.10 |
References
- github.com release-notes third-party-advisory
- github.com release-notes third-party-advisory