CVE-2022-36363 A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO!....
- Published
- Updated
- Exploit status
- No public exploit known
Description
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory.
Upgrade path
18 packages: 0 fixed, 18 with no fix yet.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Siemens logo 8 bm firmware | All versions | No fix listed | No fix yet |
| Siemens LOGO! 12/24RCE | All versions | No fix listed | No fix yet |
| Siemens LOGO! 12/24RCEo | All versions | No fix listed | No fix yet |
| Siemens LOGO! 230RCE | All versions | No fix listed | No fix yet |
| Siemens LOGO! 230RCEo | All versions | No fix listed | No fix yet |
| Siemens LOGO! 24CE | All versions | No fix listed | No fix yet |
| Siemens LOGO! 24CEo | All versions | No fix listed | No fix yet |
| Siemens LOGO! 24RCE | All versions | No fix listed | No fix yet |
| Siemens LOGO! 24RCEo | All versions | No fix listed | No fix yet |
| Siemens logo8 bm fs-05 firmware | All versions | No fix listed | No fix yet |
| Siemens SIPLUS LOGO! 12/24RCE | All versions | No fix listed | No fix yet |
| Siemens SIPLUS LOGO! 12/24RCEo | All versions | No fix listed | No fix yet |
| Siemens SIPLUS LOGO! 230RCE | All versions | No fix listed | No fix yet |
| Siemens SIPLUS LOGO! 230RCEo | All versions | No fix listed | No fix yet |
| Siemens SIPLUS LOGO! 24CE | All versions | No fix listed | No fix yet |
| Siemens SIPLUS LOGO! 24CEo | All versions | No fix listed | No fix yet |
| Siemens SIPLUS LOGO! 24RCE | All versions | No fix listed | No fix yet |
| Siemens SIPLUS LOGO! 24RCEo | All versions | No fix listed | No fix yet |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens LOGO! 12/24RCE | All versions | No fix listed |
| Siemens LOGO! 12/24RCEo | All versions | No fix listed |
| Siemens LOGO! 230RCE | All versions | No fix listed |
| Siemens LOGO! 230RCEo | All versions | No fix listed |
| Siemens LOGO! 24CE | All versions | No fix listed |
| Siemens LOGO! 24CEo | All versions | No fix listed |
| Siemens LOGO! 24RCE | All versions | No fix listed |
| Siemens LOGO! 24RCEo | All versions | No fix listed |
| Siemens SIPLUS LOGO! 12/24RCE | All versions | No fix listed |
| Siemens SIPLUS LOGO! 12/24RCEo | All versions | No fix listed |
| Siemens SIPLUS LOGO! 230RCE | All versions | No fix listed |
| Siemens SIPLUS LOGO! 230RCEo | All versions | No fix listed |
| Siemens SIPLUS LOGO! 24CE | All versions | No fix listed |
| Siemens SIPLUS LOGO! 24CEo | All versions | No fix listed |
| Siemens SIPLUS LOGO! 24RCE | All versions | No fix listed |
| Siemens SIPLUS LOGO! 24RCEo | All versions | No fix listed |
| Siemens logo 8 bm firmware | All versions | No fix listed |
| Siemens logo8 bm fs-05 firmware | All versions | No fix listed |
References
- cert-portal.siemens.com patch vendor-advisory
- cert-portal.siemens.com