CVE-2022-37060 FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by....
HighCVSS 7.5
EPSS 19.3%
- Published
- Updated
- Exploit status
- No public exploit known
Description
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files located outside of the server's restricted path. NOTE: The vendor has stated that with the introduction of firmware version 1.49.16 (Jan 2023) the FLIR AX8 should no longer be affected by the vulnerability reported. Latest firmware version (as of Oct 2025, was released Jun 2024) is 1.55.16.
Upgrade path
1 package: 1 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| flir ax8 firmware | <= 1.46.16 | after 1.46.16 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| flir ax8 firmware | <= 1.46.16 | No fix listed |
References
- www.flir.com product vendor-advisory
- gist.github.com exploit mitigation third-party-advisory
- packetstormsecurity.com exploit third-party-advisory vdb-entry
- www.zeroscience.mk third-party-advisory