Skip to content

CVE-2022-44457 A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.0 < V1.17.2), Mendix SAML (Mendix 8 compatib...

CriticalCVSS 9.8 EPSS 0.85%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
No known exploitation · automatable: yes · technical impact: total

Description

A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.0 < V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.1 < V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option 'Allow Idp Initiated Authentication' is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration.

Upgrade path

5 packages: 1 fixed.

PackageAffectedFixed inStatus
mendix saml < 1.17.0; >= 2.3.0, < 2.3.2; >= 3.3.0, < 3.3.4 1.17.0, 2.3.2, 3.3.4 Fixed
Siemens Mendix SAML (Mendix 7 compatible) = All versions < V1.17.0; = All versions >= V1.17.0 < V1.17.2 No fix listed Versions listed
Siemens Mendix SAML (Mendix 8 compatible) = All versions < V2.3.0; = All versions >= V2.3.0 < V2.3.2 No fix listed Versions listed
Siemens Mendix SAML (Mendix 9 compatible, New Track) = All versions < V3.3.1; = All versions >= V3.3.1 < V3.3.5 No fix listed Versions listed
Siemens Mendix SAML (Mendix 9 compatible, Upgrade Track) = All versions < V3.3.0; = All versions >= V3.3.0 < V3.3.4 No fix listed Versions listed

Affected products

ProductAffected versionsFixed in
Siemens Mendix SAML (Mendix 7 compatible) = All versions < V1.17.0 No fix listed
Siemens Mendix SAML (Mendix 7 compatible) = All versions >= V1.17.0 < V1.17.2 No fix listed
Siemens Mendix SAML (Mendix 8 compatible) = All versions < V2.3.0 No fix listed
Siemens Mendix SAML (Mendix 8 compatible) = All versions >= V2.3.0 < V2.3.2 No fix listed
Siemens Mendix SAML (Mendix 9 compatible, New Track) = All versions < V3.3.1 No fix listed
Siemens Mendix SAML (Mendix 9 compatible, New Track) = All versions >= V3.3.1 < V3.3.5 No fix listed
Siemens Mendix SAML (Mendix 9 compatible, Upgrade Track) = All versions < V3.3.0 No fix listed
Siemens Mendix SAML (Mendix 9 compatible, Upgrade Track) = All versions >= V3.3.0 < V3.3.4 No fix listed
mendix saml < 1.17.0 1.17.0
mendix saml >= 2.3.0, < 2.3.2 2.3.2
mendix saml >= 3.3.0, < 3.3.4 3.3.4

References