Skip to content

CVE-2023-28830 A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Solid Edge SE2022 (All versions < V222.0 Update 13), Solid Edge SE2023 (All versions < V223.0 Update 4), Teamcenter Visualizati...

HighCVSS 7.8 EPSS 0.33%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
No known exploitation · automatable: no · technical impact: total

Description

A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Solid Edge SE2022 (All versions < V222.0 Update 13), Solid Edge SE2023 (All versions < V223.0 Update 4), Teamcenter Visualization V13.2 (All versions < V13.2.0.15), Teamcenter Visualization V13.3 (All versions < V13.3.0.11), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted ASM file. An attacker could leverage this vulnerability to execute code in the context of the current process.

Upgrade path

8 packages: 2 fixed, 2 with no fix yet.

PackageAffectedFixed inStatus
Siemens Solid Edge SE2022 = All versions < V222.0 Update 13; = maintenance_pack_1; = maintenance_pack_2; = maintenance_pack_3 +9 more No fix listed No fix yet
Siemens Solid Edge SE2023 = All versions < V223.0 Update 4; = update_0001; = update_0002; = update_0003 +1 more No fix listed No fix yet
Siemens JT2Go < 14.2.0.5; = All versions < V14.2.0.5 14.2.0.5 Fixed
Siemens Teamcenter Visualization >= 13.2.0, < 13.2.0.15; >= 13.3.0, < 13.3.0.11; >= 14.1, < 14.1.0.11; >= 14.2, < 14.2.0.5 13.2.0.15, 13.3.0.11, 14.1.0.11, 14.2.0.5 Fixed
Siemens Teamcenter Visualization V13.2 = All versions < V13.2.0.15 No fix listed Versions listed
Siemens Teamcenter Visualization V13.3 = All versions < V13.3.0.11 No fix listed Versions listed
Siemens Teamcenter Visualization V14.1 = All versions < V14.1.0.11 No fix listed Versions listed
Siemens Teamcenter Visualization V14.2 = All versions < V14.2.0.5 No fix listed Versions listed

Affected products

ProductAffected versionsFixed in
Siemens JT2Go = All versions < V14.2.0.5 No fix listed
Siemens Solid Edge SE2022 = All versions < V222.0 Update 13 No fix listed
Siemens Solid Edge SE2023 = All versions < V223.0 Update 4 No fix listed
Siemens Teamcenter Visualization V13.2 = All versions < V13.2.0.15 No fix listed
Siemens Teamcenter Visualization V13.3 = All versions < V13.3.0.11 No fix listed
Siemens Teamcenter Visualization V14.1 = All versions < V14.1.0.11 No fix listed
Siemens Teamcenter Visualization V14.2 = All versions < V14.2.0.5 No fix listed
Siemens JT2Go < 14.2.0.5 14.2.0.5
Siemens Teamcenter Visualization >= 13.2.0, < 13.2.0.15 13.2.0.15
Siemens Teamcenter Visualization >= 13.3.0, < 13.3.0.11 13.3.0.11
Siemens Teamcenter Visualization >= 14.1, < 14.1.0.11 14.1.0.11
Siemens Teamcenter Visualization >= 14.2, < 14.2.0.5 14.2.0.5
Siemens Solid Edge SE2022 All versions No fix listed
Siemens Solid Edge SE2022 = maintenance_pack_1 No fix listed
Siemens Solid Edge SE2022 = maintenance_pack_2 No fix listed
Siemens Solid Edge SE2022 = maintenance_pack_3 No fix listed
Siemens Solid Edge SE2022 = maintenance_pack_4 No fix listed
Siemens Solid Edge SE2022 = maintenance_pack_5 No fix listed
Siemens Solid Edge SE2022 = maintenance_pack_7 No fix listed
Siemens Solid Edge SE2022 = maintenance_pack_8 No fix listed
Siemens Solid Edge SE2022 = maintenance_pack_9 No fix listed
Siemens Solid Edge SE2022 = maintenance_pack_10 No fix listed
Siemens Solid Edge SE2022 = maintenance_pack_11 No fix listed
Siemens Solid Edge SE2022 = maintenance_pack_12 No fix listed
Siemens Solid Edge SE2023 All versions No fix listed
Show 3 more
ProductAffected versionsFixed in
Siemens Solid Edge SE2023 = update_0001 No fix listed
Siemens Solid Edge SE2023 = update_0002 No fix listed
Siemens Solid Edge SE2023 = update_0003 No fix listed

References