CVE-2023-37558 CODESYS Improper Validation of Consistency within Input in multiple products
MediumCVSS 6.5
EPSS 0.63%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: partial
Description
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
Upgrade path
32 packages: 32 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| CODESYS Control for BeagleBone SL | < V4.10.0.0 | V4.10.0.0 | Fixed |
| CODESYS Control for BeagleBone SL | < 4.10.0.0 | 4.10.0.0 | Fixed |
| CODESYS Control for emPC-A/iMX6 SL | < V4.10.0.0 | V4.10.0.0 | Fixed |
| CODESYS Control for emPC-A/iMX6 SL | < 4.10.0.0 | 4.10.0.0 | Fixed |
| CODESYS Control for IOT2000 SL | < V4.10.0.0 | V4.10.0.0 | Fixed |
| CODESYS Control for IOT2000 SL | < 4.10.0.0 | 4.10.0.0 | Fixed |
| CODESYS Control for Linux SL | < V4.10.0.0 | V4.10.0.0 | Fixed |
| CODESYS Control for Linux SL | < 4.10.0.0 | 4.10.0.0 | Fixed |
| CODESYS Control for PFC100 SL | < V4.10.0.0 | V4.10.0.0 | Fixed |
| CODESYS Control for PFC100 SL | < 4.10.0.0 | 4.10.0.0 | Fixed |
| CODESYS Control for PFC200 SL | < V4.10.0.0 | V4.10.0.0 | Fixed |
| CODESYS Control for PFC200 SL | < 4.10.0.0 | 4.10.0.0 | Fixed |
| CODESYS Control for PLCnext SL | < V4.10.0.0 | V4.10.0.0 | Fixed |
| CODESYS Control for PLCnext SL | < 4.10.0.0 | 4.10.0.0 | Fixed |
| CODESYS Control for Raspberry Pi SL | < V4.10.0.0 | V4.10.0.0 | Fixed |
| CODESYS Control for Raspberry Pi SL | < 4.10.0.0 | 4.10.0.0 | Fixed |
| CODESYS Control for WAGO Touch Panels 600 SL | < V4.10.0.0 | V4.10.0.0 | Fixed |
| CODESYS Control for WAGO Touch Panels 600 SL | < 4.10.0.0 | 4.10.0.0 | Fixed |
| CODESYS Control RTE (for Beckhoff CX) SL | < V3.5.19.20 | V3.5.19.20 | Fixed |
| CODESYS Control RTE (SL) | < V3.5.19.20 | V3.5.19.20 | Fixed |
| CODESYS Control RTE (SL) | < 3.5.19.20 | 3.5.19.20 | Fixed |
| CODESYS control rte sl for beckhoff cx | < 3.5.19.20 | 3.5.19.20 | Fixed |
| CODESYS Control Runtime System Toolkit | < V3.5.19.20 | V3.5.19.20 | Fixed |
| CODESYS control runtime system toolkit | < 3.5.19.20 | 3.5.19.20 | Fixed |
| CODESYS Control Win (SL) | < V3.5.19.20 | V3.5.19.20 | Fixed |
| CODESYS Control Win (SL) | < 3.5.19.20 | 3.5.19.20 | Fixed |
| CODESYS development system | < 3.5.19.20 | 3.5.19.20 | Fixed |
| CODESYS Development System V3 | < V3.5.19.20 | V3.5.19.20 | Fixed |
| CODESYS hmi | < 3.5.19.20 | 3.5.19.20 | Fixed |
| CODESYS HMI (SL) | < V3.5.19.20 | V3.5.19.20 | Fixed |
… and 2 more packages.
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| CODESYS Control for BeagleBone SL | < V4.10.0.0 | V4.10.0.0 |
| CODESYS Control for emPC-A/iMX6 SL | < V4.10.0.0 | V4.10.0.0 |
| CODESYS Control for IOT2000 SL | < V4.10.0.0 | V4.10.0.0 |
| CODESYS Control for Linux SL | < V4.10.0.0 | V4.10.0.0 |
| CODESYS Control for PFC100 SL | < V4.10.0.0 | V4.10.0.0 |
| CODESYS Control for PFC200 SL | < V4.10.0.0 | V4.10.0.0 |
| CODESYS Control for PLCnext SL | < V4.10.0.0 | V4.10.0.0 |
| CODESYS Control for Raspberry Pi SL | < V4.10.0.0 | V4.10.0.0 |
| CODESYS Control for WAGO Touch Panels 600 SL | < V4.10.0.0 | V4.10.0.0 |
| CODESYS Control RTE (for Beckhoff CX) SL | < V3.5.19.20 | V3.5.19.20 |
| CODESYS Control RTE (SL) | < V3.5.19.20 | V3.5.19.20 |
| CODESYS Control Runtime System Toolkit | < V3.5.19.20 | V3.5.19.20 |
| CODESYS Control Win (SL) | < V3.5.19.20 | V3.5.19.20 |
| CODESYS Development System V3 | < V3.5.19.20 | V3.5.19.20 |
| CODESYS HMI (SL) | < V3.5.19.20 | V3.5.19.20 |
| CODESYS Safety SIL2 Runtime Toolkit | < V3.5.19.20 | V3.5.19.20 |
| CODESYS Control for BeagleBone SL | < 4.10.0.0 | 4.10.0.0 |
| CODESYS Control for emPC-A/iMX6 SL | < 4.10.0.0 | 4.10.0.0 |
| CODESYS Control for IOT2000 SL | < 4.10.0.0 | 4.10.0.0 |
| CODESYS Control for Linux SL | < 4.10.0.0 | 4.10.0.0 |
| CODESYS Control for PFC100 SL | < 4.10.0.0 | 4.10.0.0 |
| CODESYS Control for PFC200 SL | < 4.10.0.0 | 4.10.0.0 |
| CODESYS Control for PLCnext SL | < 4.10.0.0 | 4.10.0.0 |
| CODESYS Control for Raspberry Pi SL | < 4.10.0.0 | 4.10.0.0 |
| CODESYS Control for WAGO Touch Panels 600 SL | < 4.10.0.0 | 4.10.0.0 |
Show 7 more
| Product | Affected versions | Fixed in |
|---|---|---|
| CODESYS Control RTE (SL) | < 3.5.19.20 | 3.5.19.20 |
| CODESYS control rte sl for beckhoff cx | < 3.5.19.20 | 3.5.19.20 |
| CODESYS control runtime system toolkit | < 3.5.19.20 | 3.5.19.20 |
| CODESYS Control Win (SL) | < 3.5.19.20 | 3.5.19.20 |
| CODESYS development system | < 3.5.19.20 | 3.5.19.20 |
| CODESYS hmi | < 3.5.19.20 | 3.5.19.20 |
| CODESYS Safety SIL2 | < 3.5.19.20 | 3.5.19.20 |
References
- cert.vde.com third-party-advisory