CVE-2023-46280 A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC N...
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: partial
Description
A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions < V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions < V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2), SINEC NMS (All versions < V3.0 SP1). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.
Upgrade path
33 packages: 27 fixed, 6 with no fix yet.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Siemens Security Configuration Tool (SCT) | All versions | No fix listed | No fix yet |
| Siemens SIMATIC NET PC Software V17 | All versions | No fix listed | No fix yet |
| Siemens SIMATIC WinCC OA V3.17 | All versions | No fix listed | No fix yet |
| Siemens SIMATIC WinCC V7.4 | All versions | No fix listed | No fix yet |
| Siemens Totally Integrated Automation Portal (TIA Portal) V15.1 | All versions | No fix listed | No fix yet |
| Siemens Totally Integrated Automation Portal (TIA Portal) V16 | All versions | No fix listed | No fix yet |
| Siemens simatic automation tool | < V5.0 SP2 | V5.0 SP2 | Fixed |
| Siemens SIMATIC BATCH V9.1 | < V9.1 SP2 Upd5 | V9.1 SP2 Upd5 | Fixed |
| Siemens SIMATIC NET PC Software V16 | < V16 Update 8 | V16 Update 8 | Fixed |
| Siemens SIMATIC NET PC Software V18 | < V18 SP1 | V18 SP1 | Fixed |
| Siemens SIMATIC NET PC Software V19 | < V19 Update 2 | V19 Update 2 | Fixed |
| Siemens SIMATIC PCS 7 V9.1 | < V9.1 SP2 UC05 | V9.1 SP2 UC05 | Fixed |
| Siemens SIMATIC PDM V9.2 | < V9.2 SP2 Upd3 | V9.2 SP2 Upd3 | Fixed |
| Siemens SIMATIC Route Control V9.1 | < V9.1 SP2 Upd3 | V9.1 SP2 Upd3 | Fixed |
| Siemens SIMATIC S7-PCT | < V3.5 SP3 Update 6 | V3.5 SP3 Update 6 | Fixed |
| Siemens SIMATIC STEP 7 V5 | < V5.7 SP3 | V5.7 SP3 | Fixed |
| Siemens SIMATIC WinCC OA V3.18 | < V3.18 P025 | V3.18 P025 | Fixed |
| Siemens SIMATIC WinCC OA V3.19 | < V3.19 P010 | V3.19 P010 | Fixed |
| Siemens SIMATIC WinCC Runtime Advanced | < V17 Update 8 | V17 Update 8 | Fixed |
| Siemens SIMATIC WinCC Runtime Professional V16 | < V16 Update 6 | V16 Update 6 | Fixed |
| Siemens SIMATIC WinCC Runtime Professional V17 | < V17 Update 8 | V17 Update 8 | Fixed |
| Siemens SIMATIC WinCC Runtime Professional V18 | < V18 Update 4 | V18 Update 4 | Fixed |
| Siemens SIMATIC WinCC Runtime Professional V19 | < V19 Update 2 | V19 Update 2 | Fixed |
| Siemens SIMATIC WinCC V7.5 | < V7.5 SP2 Update 17 | V7.5 SP2 Update 17 | Fixed |
| Siemens SIMATIC WinCC V8.0 | < V8.0 Update 5 | V8.0 Update 5 | Fixed |
| Siemens SINAMICS Startdrive | < V19 SP1 | V19 SP1 | Fixed |
| Siemens SINEC NMS | < V3.0; < V3.0 SP1 | V3.0, V3.0 SP1 | Fixed |
| Siemens SINUMERIK ONE virtual | < V6.23 | V6.23 | Fixed |
| Siemens SINUMERIK PLC Programming Tool | < V3.3.12 | V3.3.12 | Fixed |
| Siemens TIA Portal Cloud Connector | < V2.0 | V2.0 | Fixed |
… and 3 more packages.
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens Security Configuration Tool (SCT) | All versions | No fix listed |
| Siemens simatic automation tool | < V5.0 SP2 | V5.0 SP2 |
| Siemens SIMATIC BATCH V9.1 | < V9.1 SP2 Upd5 | V9.1 SP2 Upd5 |
| Siemens SIMATIC NET PC Software V16 | < V16 Update 8 | V16 Update 8 |
| Siemens SIMATIC NET PC Software V17 | All versions | No fix listed |
| Siemens SIMATIC NET PC Software V18 | < V18 SP1 | V18 SP1 |
| Siemens SIMATIC NET PC Software V19 | < V19 Update 2 | V19 Update 2 |
| Siemens SIMATIC PCS 7 V9.1 | < V9.1 SP2 UC05 | V9.1 SP2 UC05 |
| Siemens SIMATIC PDM V9.2 | < V9.2 SP2 Upd3 | V9.2 SP2 Upd3 |
| Siemens SIMATIC Route Control V9.1 | < V9.1 SP2 Upd3 | V9.1 SP2 Upd3 |
| Siemens SIMATIC S7-PCT | < V3.5 SP3 Update 6 | V3.5 SP3 Update 6 |
| Siemens SIMATIC STEP 7 V5 | < V5.7 SP3 | V5.7 SP3 |
| Siemens SIMATIC WinCC OA V3.17 | All versions | No fix listed |
| Siemens SIMATIC WinCC OA V3.18 | < V3.18 P025 | V3.18 P025 |
| Siemens SIMATIC WinCC OA V3.19 | < V3.19 P010 | V3.19 P010 |
| Siemens SIMATIC WinCC Runtime Advanced | < V17 Update 8 | V17 Update 8 |
| Siemens SIMATIC WinCC Runtime Professional V16 | < V16 Update 6 | V16 Update 6 |
| Siemens SIMATIC WinCC Runtime Professional V17 | < V17 Update 8 | V17 Update 8 |
| Siemens SIMATIC WinCC Runtime Professional V18 | < V18 Update 4 | V18 Update 4 |
| Siemens SIMATIC WinCC Runtime Professional V19 | < V19 Update 2 | V19 Update 2 |
| Siemens SIMATIC WinCC V7.4 | All versions | No fix listed |
| Siemens SIMATIC WinCC V7.5 | < V7.5 SP2 Update 17 | V7.5 SP2 Update 17 |
| Siemens SIMATIC WinCC V8.0 | < V8.0 Update 5 | V8.0 Update 5 |
| Siemens SINAMICS Startdrive | < V19 SP1 | V19 SP1 |
| Siemens SINEC NMS | < V3.0 | V3.0 |
Show 9 more
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens SINUMERIK ONE virtual | < V6.23 | V6.23 |
| Siemens SINUMERIK PLC Programming Tool | < V3.3.12 | V3.3.12 |
| Siemens TIA Portal Cloud Connector | < V2.0 | V2.0 |
| Siemens Totally Integrated Automation Portal (TIA Portal) V15.1 | All versions | No fix listed |
| Siemens Totally Integrated Automation Portal (TIA Portal) V16 | All versions | No fix listed |
| Siemens Totally Integrated Automation Portal (TIA Portal) V17 | < V17 Update 8 | V17 Update 8 |
| Siemens Totally Integrated Automation Portal (TIA Portal) V18 | < V18 Update 4 | V18 Update 4 |
| Siemens Totally Integrated Automation Portal (TIA Portal) V19 | < V19 Update 2 | V19 Update 2 |
| Siemens SINEC NMS | < V3.0 SP1 | V3.0 SP1 |