Skip to content

CVE-2023-46285 A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V...

HighCVSS 7.5 EPSS 1.0%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
No known exploitation · automatable: yes · technical impact: partial

Description

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.

Upgrade path

11 packages: 5 fixed, 2 partially fixed, 4 with no fix yet.

PackageAffectedFixed inStatus
Siemens sinumerik integrate runmyhmi automotive All versions No fix listed No fix yet
Siemens Totally Integrated Automation Portal (TIA Portal) V14 All versions No fix listed No fix yet
Siemens Totally Integrated Automation Portal (TIA Portal) V15.1 All versions No fix listed No fix yet
Siemens Totally Integrated Automation Portal (TIA Portal) V16 All versions No fix listed No fix yet
Siemens Opcenter Quality < V2312; All versions V2312 Partially fixed
Siemens totally integrated automation portal = 18; = 18-update_1; >= 14.0, < 15; >= 15, < 16 +3 more 15, 16, 17, 18 Partially fixed
Siemens Opcenter Execution Foundation < V2407 V2407 Fixed
Siemens SIMATIC PCS neo < 4.1; < V4.1 4.1, V4.1 Fixed
Siemens SINEC NMS < V2.0 SP1 V2.0 SP1 Fixed
Siemens Totally Integrated Automation Portal (TIA Portal) V17 < V17 Update 8 V17 Update 8 Fixed
Siemens Totally Integrated Automation Portal (TIA Portal) V18 < V18 Update 3 V18 Update 3 Fixed

Affected products

ProductAffected versionsFixed in
Siemens Opcenter Execution Foundation < V2407 V2407
Siemens Opcenter Quality < V2312 V2312
Siemens SIMATIC PCS neo < V4.1 V4.1
Siemens SINEC NMS < V2.0 SP1 V2.0 SP1
Siemens Totally Integrated Automation Portal (TIA Portal) V14 All versions No fix listed
Siemens Totally Integrated Automation Portal (TIA Portal) V15.1 All versions No fix listed
Siemens Totally Integrated Automation Portal (TIA Portal) V16 All versions No fix listed
Siemens Totally Integrated Automation Portal (TIA Portal) V17 < V17 Update 8 V17 Update 8
Siemens Totally Integrated Automation Portal (TIA Portal) V18 < V18 Update 3 V18 Update 3
Siemens Opcenter Quality All versions No fix listed
Siemens SIMATIC PCS neo < 4.1 4.1
Siemens sinumerik integrate runmyhmi automotive All versions No fix listed
Siemens totally integrated automation portal >= 14.0, < 15 15
Siemens totally integrated automation portal >= 15, < 16 16
Siemens totally integrated automation portal >= 16, < 17 17
Siemens totally integrated automation portal >= 17, < 18 18
Siemens totally integrated automation portal All versions No fix listed
Siemens totally integrated automation portal = 18 No fix listed
Siemens totally integrated automation portal = 18-update_1 No fix listed

References