CVE-2023-49125 A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.263), Parasolid V35.1 (All versions < V35.1.252), Parasolid V36.0 (All versions < V36.0.198), Solid Edge SE2023 (All versio...
HighCVSS 7.8
EPSS 0.30%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: total
Description
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.263), Parasolid V35.1 (All versions < V35.1.252), Parasolid V36.0 (All versions < V36.0.198), Solid Edge SE2023 (All versions < V223.0 Update 11), Solid Edge SE2024 (All versions < V224.0 Update 3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process.
Upgrade path
6 packages: 6 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Siemens parasolid | >= 35.0, < 35.0.263; >= 35.1, < 35.1.252; >= 36.0, < 36.0.198 | 35.0.263, 35.1.252, 36.0.198 | Fixed |
| Siemens Parasolid V35.0 | < V35.0.263 | V35.0.263 | Fixed |
| Siemens Parasolid V35.1 | < V35.1.252 | V35.1.252 | Fixed |
| Siemens Parasolid V36.0 | < V36.0.198 | V36.0.198 | Fixed |
| Siemens Solid Edge SE2023 | < 223.0; < V223.0 Update 11; = 223.0-update_0001; = 223.0-update_0002 +8 more | 223.0, V223.0 Update 11 | Fixed |
| Siemens Solid Edge SE2024 | < 224.0; < V224.0 Update 3; = 224.0-update_0001; = 224.0-update_0002 | 224.0, V224.0 Update 3 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens Parasolid V35.0 | < V35.0.263 | V35.0.263 |
| Siemens Parasolid V35.1 | < V35.1.252 | V35.1.252 |
| Siemens Parasolid V36.0 | < V36.0.198 | V36.0.198 |
| Siemens Solid Edge SE2023 | < V223.0 Update 11 | V223.0 Update 11 |
| Siemens Solid Edge SE2024 | < V224.0 Update 3 | V224.0 Update 3 |
| Siemens parasolid | >= 35.0, < 35.0.263 | 35.0.263 |
| Siemens parasolid | >= 35.1, < 35.1.252 | 35.1.252 |
| Siemens parasolid | >= 36.0, < 36.0.198 | 36.0.198 |
| Siemens Solid Edge SE2023 | < 223.0 | 223.0 |
| Siemens Solid Edge SE2023 | = 223.0-update_0001 | No fix listed |
| Siemens Solid Edge SE2023 | = 223.0-update_0002 | No fix listed |
| Siemens Solid Edge SE2023 | = 223.0-update_0003 | No fix listed |
| Siemens Solid Edge SE2023 | = 223.0-update_0004 | No fix listed |
| Siemens Solid Edge SE2023 | = 223.0-update_0005 | No fix listed |
| Siemens Solid Edge SE2023 | = 223.0-update_0006 | No fix listed |
| Siemens Solid Edge SE2023 | = 223.0-update_0007 | No fix listed |
| Siemens Solid Edge SE2023 | = 223.0-update_0008 | No fix listed |
| Siemens Solid Edge SE2023 | = 223.0-update_0009 | No fix listed |
| Siemens Solid Edge SE2023 | = 223.0-update_0010 | No fix listed |
| Siemens Solid Edge SE2024 | < 224.0 | 224.0 |
| Siemens Solid Edge SE2024 | = 224.0-update_0001 | No fix listed |
| Siemens Solid Edge SE2024 | = 224.0-update_0002 | No fix listed |
References
- cert-portal.siemens.com vendor-advisory