CVE-2023-51745 A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcen...
HighCVSS 7.8
EPSS 0.26%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: total
Description
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Upgrade path
6 packages: 2 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Siemens JT2Go | < 14.3.0.6; = All versions < V14.3.0.6 | 14.3.0.6 | Fixed |
| Siemens Teamcenter Visualization | >= 13.3.0, < 13.3.0.13; >= 14.1, < 14.1.0.12; >= 14.2, < 14.2.0.9; >= 14.3, < 14.3.0.6 | 13.3.0.13, 14.1.0.12, 14.2.0.9, 14.3.0.6 | Fixed |
| Siemens Teamcenter Visualization V13.3 | = All versions < V13.3.0.13 | No fix listed | Versions listed |
| Siemens Teamcenter Visualization V14.1 | = All versions < V14.1.0.12 | No fix listed | Versions listed |
| Siemens Teamcenter Visualization V14.2 | = All versions < V14.2.0.9 | No fix listed | Versions listed |
| Siemens Teamcenter Visualization V14.3 | = All versions < V14.3.0.6 | No fix listed | Versions listed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens JT2Go | = All versions < V14.3.0.6 | No fix listed |
| Siemens Teamcenter Visualization V13.3 | = All versions < V13.3.0.13 | No fix listed |
| Siemens Teamcenter Visualization V14.1 | = All versions < V14.1.0.12 | No fix listed |
| Siemens Teamcenter Visualization V14.2 | = All versions < V14.2.0.9 | No fix listed |
| Siemens Teamcenter Visualization V14.3 | = All versions < V14.3.0.6 | No fix listed |
| Siemens JT2Go | < 14.3.0.6 | 14.3.0.6 |
| Siemens Teamcenter Visualization | >= 13.3.0, < 13.3.0.13 | 13.3.0.13 |
| Siemens Teamcenter Visualization | >= 14.1, < 14.1.0.12 | 14.1.0.12 |
| Siemens Teamcenter Visualization | >= 14.2, < 14.2.0.9 | 14.2.0.9 |
| Siemens Teamcenter Visualization | >= 14.3, < 14.3.0.6 | 14.3.0.6 |
References