CVE-2024-10351 Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow
HighCVSS 8.7
EPSS 0.87%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: total
Description
A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Upgrade path
2 packages: 0 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| tenda RX9 Pro | = 22.03.02.20 | No fix listed | Versions listed |
| tenda rx9 pro firmware | = 22.03.02.20 | No fix listed | Versions listed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| tenda RX9 Pro | = 22.03.02.20 | No fix listed |
| tenda rx9 pro firmware | = 22.03.02.20 | No fix listed |
References
- VDB-281699 | Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow technical-description third-party-advisory vdb-entry
- VDB-281699 | CTI Indicators (IOB, IOC, IOA) permissions-required signature vdb-entry
- Submit #427706 | Tenda Rx9 Router RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow third-party-advisory vdb-entry
- gitee.com exploit permissions-required
- www.tenda.com.cn product