CVE-2024-3640 Rockwell Automation FactoryTalk® Remote Access™ has Unquoted Executables
HighCVSS 7.0
EPSS 0.37%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: total
Description
An unquoted executable path exists in the Rockwell Automation FactoryTalk® Remote Access™ possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a System user. A threat actor needs admin privileges to exploit this vulnerability.
Upgrade path
1 package: 0 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Rockwell Automation FactoryTalk® Remote Access™ | = v13.5.0.174 | No fix listed | Versions listed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Rockwell Automation FactoryTalk® Remote Access™ | = v13.5.0.174 | No fix listed |