CVE-2024-37023 Vonets WiFi Bridges Command Injection
CriticalCVSS 9.4
EPSS 1.3%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: total
Description
Multiple OS command injection vulnerabilities affecting Vonets
industrial wifi bridge relays and wifi bridge repeaters, software
versions 3.3.23.6.9 and prior, enable an authenticated remote attacker
to execute arbitrary OS commands via various endpoint parameters.
Upgrade path
28 packages: 28 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| vonets VAP11AC | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets vap11ac firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VAP11G | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets vap11g firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VAP11G-300 | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets vap11g-300 firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VAP11G-500 | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets vap11g-500 firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VAP11G-500S | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets vap11g-500s firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VAP11N-300 | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets vap11n-300 firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VAP11S | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets vap11s firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VAP11S-5G | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets vap11s-5g firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VAR11N-300 | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets var11n-300 firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VAR1200-H | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets var1200-h firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VAR1200-L | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets var1200-l firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VAR600-H | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets var600-h firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VBG1200 | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets vbg1200 firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets VGA-1000 | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
| vonets vga-1000 firmware | <= 3.3.23.6.9 | after 3.3.23.6.9 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| vonets VAR1200-H | <= 3.3.23.6.9 | No fix listed |
| vonets VAR1200-L | <= 3.3.23.6.9 | No fix listed |
| vonets VAR600-H | <= 3.3.23.6.9 | No fix listed |
| vonets VAP11AC | <= 3.3.23.6.9 | No fix listed |
| vonets VAP11G-500S | <= 3.3.23.6.9 | No fix listed |
| vonets VBG1200 | <= 3.3.23.6.9 | No fix listed |
| vonets VAP11S-5G | <= 3.3.23.6.9 | No fix listed |
| vonets VAP11S | <= 3.3.23.6.9 | No fix listed |
| vonets VAR11N-300 | <= 3.3.23.6.9 | No fix listed |
| vonets VAP11G-300 | <= 3.3.23.6.9 | No fix listed |
| vonets VAP11N-300 | <= 3.3.23.6.9 | No fix listed |
| vonets VAP11G | <= 3.3.23.6.9 | No fix listed |
| vonets VAP11G-500 | <= 3.3.23.6.9 | No fix listed |
| vonets VGA-1000 | <= 3.3.23.6.9 | No fix listed |
| vonets var1200-h firmware | <= 3.3.23.6.9 | No fix listed |
| vonets var1200-l firmware | <= 3.3.23.6.9 | No fix listed |
| vonets var600-h firmware | <= 3.3.23.6.9 | No fix listed |
| vonets vap11ac firmware | <= 3.3.23.6.9 | No fix listed |
| vonets vap11g-500s firmware | <= 3.3.23.6.9 | No fix listed |
| vonets vbg1200 firmware | <= 3.3.23.6.9 | No fix listed |
| vonets vap11s-5g firmware | <= 3.3.23.6.9 | No fix listed |
| vonets vap11s firmware | <= 3.3.23.6.9 | No fix listed |
| vonets var11n-300 firmware | <= 3.3.23.6.9 | No fix listed |
| vonets vap11n-300 firmware | <= 3.3.23.6.9 | No fix listed |
| vonets vap11g firmware | <= 3.3.23.6.9 | No fix listed |
Show 3 more
| Product | Affected versions | Fixed in |
|---|---|---|
| vonets vga-1000 firmware | <= 3.3.23.6.9 | No fix listed |
| vonets vap11g-300 firmware | <= 3.3.23.6.9 | No fix listed |
| vonets vap11g-500 firmware | <= 3.3.23.6.9 | No fix listed |
References
- www.cisa.gov third-party-advisory us-government-resource