CVE-2024-37036 CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
CriticalCVSS 9.8
EPSS 0.53%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: yes · technical impact: total
Description
CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass
when sending a malformed POST request and particular configuration parameters are set.
Upgrade path
13 packages: 7 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Schneider Electric sage 1410 firmware | <= C3414-500-S02K5_P8 | after C3414-500-S02K5_P8 | Fixed |
| Schneider Electric sage 1430 firmware | <= C3414-500-S02K5_P8 | after C3414-500-S02K5_P8 | Fixed |
| Schneider Electric sage 1450 firmware | <= C3414-500-S02K5_P8 | after C3414-500-S02K5_P8 | Fixed |
| Schneider Electric sage 2400 firmware | <= C3414-500-S02K5_P8 | after C3414-500-S02K5_P8 | Fixed |
| Schneider Electric sage 3030 magnum firmware | <= C3414-500-S02K5_P8 | after C3414-500-S02K5_P8 | Fixed |
| Schneider Electric sage 4400 firmware | <= C3414-500-S02K5_P8 | after C3414-500-S02K5_P8 | Fixed |
| schneider-electric sage rtu firmware | <= c3414-500-s02k5_p8 | after c3414-500-s02k5_p8 | Fixed |
| Schneider Electric Sage 1410 | = Versions C3414-500-S02K5_P8 and prior | No fix listed | Versions listed |
| Schneider Electric Sage 1430 | = Versions C3414-500-S02K5_P8 and prior | No fix listed | Versions listed |
| Schneider Electric Sage 1450 | = Versions C3414-500-S02K5_P8 and prior | No fix listed | Versions listed |
| Schneider Electric Sage 2400 | = Versions C3414-500-S02K5_P8 and prior | No fix listed | Versions listed |
| Schneider Electric Sage 3030 Magnum | = Versions C3414-500-S02K5_P8 and prior | No fix listed | Versions listed |
| Schneider Electric Sage 4400 | = Versions C3414-500-S02K5_P8 and prior | No fix listed | Versions listed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Schneider Electric Sage 1410 | = Versions C3414-500-S02K5_P8 and prior | No fix listed |
| Schneider Electric Sage 1430 | = Versions C3414-500-S02K5_P8 and prior | No fix listed |
| Schneider Electric Sage 1450 | = Versions C3414-500-S02K5_P8 and prior | No fix listed |
| Schneider Electric Sage 2400 | = Versions C3414-500-S02K5_P8 and prior | No fix listed |
| Schneider Electric Sage 3030 Magnum | = Versions C3414-500-S02K5_P8 and prior | No fix listed |
| Schneider Electric Sage 4400 | = Versions C3414-500-S02K5_P8 and prior | No fix listed |
| Schneider Electric sage 1410 firmware | <= C3414-500-S02K5_P8 | No fix listed |
| Schneider Electric sage 1430 firmware | <= C3414-500-S02K5_P8 | No fix listed |
| Schneider Electric sage 1450 firmware | <= C3414-500-S02K5_P8 | No fix listed |
| Schneider Electric sage 2400 firmware | <= C3414-500-S02K5_P8 | No fix listed |
| Schneider Electric sage 3030 magnum firmware | <= C3414-500-S02K5_P8 | No fix listed |
| Schneider Electric sage 4400 firmware | <= C3414-500-S02K5_P8 | No fix listed |
| schneider-electric sage rtu firmware | <= c3414-500-s02k5_p8 | No fix listed |
References
- download.schneider-electric.com vendor-advisory