CVE-2024-43099 AutomationDirect DirectLogic H2-DM1E Authentication Bypass by Capture-replay
HighCVSS 8.7
EPSS 0.44%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: total
Description
The session hijacking attack targets the application layer's control mechanism, which manages authenticated sessions between a host PC and a PLC. During such sessions, a session key is utilized to maintain security. However, if an attacker captures this session key, they can inject traffic into an ongoing authenticated session. To successfully achieve this, the attacker also needs to spoof both the IP address and MAC address of the originating host which is typical of a session-based attack.
Upgrade path
2 packages: 2 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| AutomationDirect DirectLogic H2-DM1E | <= 2.8.0 | after 2.8.0 | Fixed |
| AutomationDirect h2-dm1e firmware | <= 2.8.0 | after 2.8.0 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| AutomationDirect DirectLogic H2-DM1E | <= 2.8.0 | No fix listed |
| AutomationDirect h2-dm1e firmware | <= 2.8.0 | No fix listed |