Skip to content

CVE-2024-43656 A backup can be manipulated and then restored to create arbitrary files inside the <redacted> directory. A CGI script can be added to the web directory this way, allowing for full remote code executio...

CriticalCVSS 9.3 EPSS 1.5%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
No known exploitation · automatable: no · technical impact: total

Description

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root

This issue affects Iocharger firmware for AC model chargers before version 24120701.

Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.

Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.

CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Upgrade path

1 package: 1 fixed.

PackageAffectedFixed inStatus
Iocharger firmware for AC models < 24120701 24120701 Fixed

Affected products

ProductAffected versionsFixed in
Iocharger firmware for AC models < 24120701 24120701

References