CVE-2024-8751 CVE-2024-8751
HighCVSS 7.5
EPSS 0.93%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: yes · technical impact: partial
Description
A vulnerability allows a remote unauthenticated attacker to modify the prod
uct’s IP address over the Sopas ET interface. This can lead to a Denial of Service attack.
Upgrade path
18 packages: 2 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| SICK AG MSC800 | >= S1.0, <= <=S2.93.19; >= V1.0, <= <=V4.25 | after <=S2.93.19, <=V4.25 | Fixed |
| SICK AG msc800 firmware | >= 1.0, <= 4.25; >= 1.0, <= s2.93.19 | after 4.25, s2.93.19 | Fixed |
| Endress+Hauser FLPS | = all versions | No fix listed | Versions listed |
| Endress+Hauser GM32 | = all versions | No fix listed | Versions listed |
| Endress+Hauser GMS800 | = all versions | No fix listed | Versions listed |
| Endress+Hauser GMS800 FIDOR | = all versions | No fix listed | Versions listed |
| Endress+Hauser MARSIC200 | = all versions | No fix listed | Versions listed |
| Endress+Hauser MARSIC280 | = all versions | No fix listed | Versions listed |
| Endress+Hauser MARSIC300 | = all versions | No fix listed | Versions listed |
| Endress+Hauser MCS100FT | = all versions | No fix listed | Versions listed |
| Endress+Hauser MCS200HW | = all versions | No fix listed | Versions listed |
| Endress+Hauser MCS300P | = all versions | No fix listed | Versions listed |
| Endress+Hauser MCU ETH-Service and Modbus-TCP Module | = all versions | No fix listed | Versions listed |
| Endress+Hauser MERCEM300Z | = all versions | No fix listed | Versions listed |
| Endress+Hauser MES1B B&B Converter | = all versions | No fix listed | Versions listed |
| Endress+Hauser SAM800 | = all versions | No fix listed | Versions listed |
| Endress+Hauser SIPROCESS | = all versions | No fix listed | Versions listed |
| Endress+Hauser VICOTEC320 | = all versions | No fix listed | Versions listed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| SICK AG MSC800 | >= V1.0, <= <=V4.25 | No fix listed |
| SICK AG MSC800 | >= S1.0, <= <=S2.93.19 | No fix listed |
| Endress+Hauser MARSIC200 | = all versions | No fix listed |
| Endress+Hauser MARSIC280 | = all versions | No fix listed |
| Endress+Hauser MARSIC300 | = all versions | No fix listed |
| Endress+Hauser MCS100FT | = all versions | No fix listed |
| Endress+Hauser MCS200HW | = all versions | No fix listed |
| Endress+Hauser MCS300P | = all versions | No fix listed |
| Endress+Hauser MERCEM300Z | = all versions | No fix listed |
| Endress+Hauser SAM800 | = all versions | No fix listed |
| Endress+Hauser SIPROCESS | = all versions | No fix listed |
| Endress+Hauser GMS800 | = all versions | No fix listed |
| Endress+Hauser GMS800 FIDOR | = all versions | No fix listed |
| Endress+Hauser GM32 | = all versions | No fix listed |
| Endress+Hauser VICOTEC320 | = all versions | No fix listed |
| Endress+Hauser MCU ETH-Service and Modbus-TCP Module | = all versions | No fix listed |
| Endress+Hauser FLPS | = all versions | No fix listed |
| Endress+Hauser MES1B B&B Converter | = all versions | No fix listed |
| SICK AG msc800 firmware | >= 1.0, <= 4.25 | No fix listed |
| SICK AG msc800 firmware | >= 1.0, <= s2.93.19 | No fix listed |
References
- sick.com
- cdn.sick.com
- www.cisa.gov
- www.first.org
- www.sick.com vendor-advisory
- www.sick.com vendor-advisory
- www.sick.com
- www.sick.com
- www.endress.com