Skip to content

CVE-2025-1038 The “Diagnostics Tools” page of the web-based configuration utility does not properly validate user-controlled input, allowing an authenticated user with high privileges to inject commands into the co...

HighCVSS 7.5 EPSS 0.32%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
No known exploitation · automatable: no · technical impact: total

Description

The “Diagnostics Tools” page of the web-based configuration utility does not properly validate user-controlled input, allowing an authenticated user with high privileges to inject commands into the command shell of the TropOS 4th Gen device. The injected commands can be exploited to execute several set-uid (SUID) applications to ultimately gain root access to the TropOS device.

Upgrade path

1 package: 1 fixed.

PackageAffectedFixed inStatus
Hitachi Energy TropOS 4th Gen >= 8.7.0.0, < 8.9.6.0 8.9.6.0 Fixed

Affected products

ProductAffected versionsFixed in
Hitachi Energy TropOS 4th Gen >= 8.7.0.0, < 8.9.6.0 8.9.6.0