CVE-2025-2522 Lack of buffer clearing before reuse may result in incorrect system behavior.
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: partial
Description
The Honeywell Experion PKS and OneWireless WDM
contains Sensitive Information in Resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in buffer reuse which may cause incorrect system behavior.
Honeywell also recommends updating to the most recent version of
Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.
The affected Experion PKS products are
C300, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are 520.1 before
520.2 TCU9 HF1 and 530 before 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
Upgrade path
10 packages: 10 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| honeywell C200E | >= 520.1, <= 520.2 TCU9; >= 530, <= 530 TCU3 | after 520.2 TCU9, 530 TCU3 | Fixed |
| honeywell C300 PCNT02 | >= 520.1, <= 520.2 TCU9; >= 530, <= 530 TCU3 | after 520.2 TCU9, 530 TCU3 | Fixed |
| honeywell C300 PCNT05 | >= 520.1, <= 520.2 TCU9; >= 530, <= 530 TCU3 | after 520.2 TCU9, 530 TCU3 | Fixed |
| honeywell C300PM | >= 520.1, <= 520.2 TCU9; >= 530, <= 530 TCU3 | after 520.2 TCU9, 530 TCU3 | Fixed |
| honeywell CN100 | >= 520.1, <= 520.2 TCU9; >= 530, <= 530 TCU3 | after 520.2 TCU9, 530 TCU3 | Fixed |
| honeywell FIM4 | >= 520.1, <= 520.2 TCU9; >= 530, <= 530 TCU3 | after 520.2 TCU9, 530 TCU3 | Fixed |
| honeywell FIM8 | >= 520.1, <= 520.2 TCU9; >= 530, <= 530 TCU3 | after 520.2 TCU9, 530 TCU3 | Fixed |
| honeywell HCA | >= 520.1, <= 520.2 TCU9; >= 530, <= 530 TCU3 | after 520.2 TCU9, 530 TCU3 | Fixed |
| honeywell UOC | >= 520.1, <= 520.2 TCU9; >= 530, <= 530 TCU3 | after 520.2 TCU9, 530 TCU3 | Fixed |
| honeywell Wireless Device Manager | >= 322.1, <= 322.4; >= 330.1, <= 330.3 | after 322.4, 330.3 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| honeywell C300 PCNT02 | >= 520.1, <= 520.2 TCU9 | No fix listed |
| honeywell C300 PCNT02 | >= 530, <= 530 TCU3 | No fix listed |
| honeywell C300 PCNT05 | >= 520.1, <= 520.2 TCU9 | No fix listed |
| honeywell C300 PCNT05 | >= 530, <= 530 TCU3 | No fix listed |
| honeywell FIM4 | >= 520.1, <= 520.2 TCU9 | No fix listed |
| honeywell FIM4 | >= 530, <= 530 TCU3 | No fix listed |
| honeywell FIM8 | >= 520.1, <= 520.2 TCU9 | No fix listed |
| honeywell FIM8 | >= 530, <= 530 TCU3 | No fix listed |
| honeywell UOC | >= 520.1, <= 520.2 TCU9 | No fix listed |
| honeywell UOC | >= 530, <= 530 TCU3 | No fix listed |
| honeywell CN100 | >= 520.1, <= 520.2 TCU9 | No fix listed |
| honeywell CN100 | >= 530, <= 530 TCU3 | No fix listed |
| honeywell HCA | >= 520.1, <= 520.2 TCU9 | No fix listed |
| honeywell HCA | >= 530, <= 530 TCU3 | No fix listed |
| honeywell C300PM | >= 520.1, <= 520.2 TCU9 | No fix listed |
| honeywell C300PM | >= 530, <= 530 TCU3 | No fix listed |
| honeywell C200E | >= 520.1, <= 520.2 TCU9 | No fix listed |
| honeywell C200E | >= 530, <= 530 TCU3 | No fix listed |
| honeywell Wireless Device Manager | >= 322.1, <= 322.4 | No fix listed |
| honeywell Wireless Device Manager | >= 330.1, <= 330.3 | No fix listed |