CVE-2025-25249 A heap-based buffer overflow vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2.0 through 7.2.11, FortiOS 7.0.0 through 7.0.17, FortiOS 6.4 all versions, F...
- Published
- Updated
- Exploit status
- Exploited in the wild (confirmed)
- CISA SSVC
- Actively exploited · automatable: no · technical impact: total
- Technology
- Network Appliances
Description
A heap-based buffer overflow vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2.0 through 7.2.11, FortiOS 7.0.0 through 7.0.17, FortiOS 6.4 all versions, FortiSwitchManager 7.2.0 through 7.2.6, FortiSwitchManager 7.0.0 through 7.0.5 allows attacker to execute unauthorized code or commands via specially crafted packets
CISA Known Exploited Vulnerability
- Date added
- 2026-09-09
- Due date (FCEB)
- 2026-09-12
- Ransomware use
- Unknown
Required action
Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Upgrade path
5 packages: 2 fixed, 2 with no fix yet.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Siemens RUGGEDCOM APE1808 | All versions | No fix listed | No fix yet |
| Siemens ruggedcom ape1808 firmware | All versions | No fix listed | No fix yet |
| fortinet fortios | >= 6.4.0, < 7.0.18; >= 7.2.0, < 7.2.12; >= 7.2.4, <= 7.2.11; >= 7.4.0, < 7.4.9 +3 more | 7.0.18, 7.2.12, 7.4.9, 7.6.4 | Fixed |
| fortinet fortiswitchmanager | >= 7.0.0, < 7.0.6; >= 7.2.0, < 7.2.7; >= 7.2.2, <= 7.2.5 | 7.0.6, 7.2.7 | Fixed |
| fortinet fortisase | = 25.1.39; = 25.1.51 | No fix listed | Versions listed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| fortinet fortiswitchmanager | >= 7.2.2, <= 7.2.5 | No fix listed |
| fortinet fortios | >= 7.6.0, <= 7.6.2 | No fix listed |
| fortinet fortios | >= 7.4.0, <= 7.4.7 | No fix listed |
| fortinet fortios | >= 7.2.4, <= 7.2.11 | No fix listed |
| Siemens RUGGEDCOM APE1808 | All versions | No fix listed |
| fortinet fortios | >= 6.4.0, < 7.0.18 | 7.0.18 |
| fortinet fortios | >= 7.2.0, < 7.2.12 | 7.2.12 |
| fortinet fortios | >= 7.4.0, < 7.4.9 | 7.4.9 |
| fortinet fortios | >= 7.6.0, < 7.6.4 | 7.6.4 |
| fortinet fortiswitchmanager | >= 7.0.0, < 7.0.6 | 7.0.6 |
| fortinet fortiswitchmanager | >= 7.2.0, < 7.2.7 | 7.2.7 |
| fortinet fortisase | = 25.1.39 | No fix listed |
| fortinet fortisase | = 25.1.51 | No fix listed |
| Siemens ruggedcom ape1808 firmware | All versions | No fix listed |
References
- https://fortiguard.fortinet.com/psirt/FG-IR-25-084 mitigation vendor-advisory
- socradar.io exploit third-party-advisory
- www.cisa.gov government-resource us-government-resource
- cert-portal.siemens.com third-party-advisory
- ENISA EUVD EUVD-2026-2223 third-party-advisory