CVE-2025-52586 EG4 Electronics EG4 Inverters Cleartext Transmission of Sensitive Information
HighCVSS 7.5
EPSS 0.09%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: partial
Description
The MOD3 command traffic between the monitoring application and the
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings.
Upgrade path
7 packages: 0 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| EG4 Electronics EG4 12000XP | = all versions | No fix listed | Versions listed |
| EG4 Electronics EG4 12kPV | = all versions | No fix listed | Versions listed |
| EG4 Electronics EG4 18kPV | = all versions | No fix listed | Versions listed |
| EG4 Electronics EG4 6000XP | = all versions | No fix listed | Versions listed |
| EG4 Electronics EG4 Flex 18 | = all versions | No fix listed | Versions listed |
| EG4 Electronics EG4 Flex 21 | = all versions | No fix listed | Versions listed |
| EG4 Electronics EG4 GridBoss | = all versions | No fix listed | Versions listed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| EG4 Electronics EG4 12kPV | = all versions | No fix listed |
| EG4 Electronics EG4 18kPV | = all versions | No fix listed |
| EG4 Electronics EG4 Flex 21 | = all versions | No fix listed |
| EG4 Electronics EG4 Flex 18 | = all versions | No fix listed |
| EG4 Electronics EG4 6000XP | = all versions | No fix listed |
| EG4 Electronics EG4 12000XP | = all versions | No fix listed |
| EG4 Electronics EG4 GridBoss | = all versions | No fix listed |