Skip to content

CVE-2025-59703 Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a Physically Proximate Attacker to access the internal components o...

CriticalCVSS 9.1 EPSS 0.50%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
Proof of concept public · automatable: yes · technical impact: total

Description

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from the device without damaging it. This is called an F14 attack.

Upgrade path

5 packages: 5 fixed.

PackageAffectedFixed inStatus
entrust nshield 5c firmware < 13.6.12; >= 13.7, < 13.9.0 13.6.12, 13.9.0 Fixed
entrust nshield connect xc base firmware < 13.6.12; >= 13.7, < 13.9.0 13.6.12, 13.9.0 Fixed
entrust nshield connect xc high firmware < 13.6.12; >= 13.7, < 13.9.0 13.6.12, 13.9.0 Fixed
entrust nshield connect xc mid firmware < 13.6.12; >= 13.7, < 13.9.0 13.6.12, 13.9.0 Fixed
entrust nshield hsmi firmware < 13.6.12; >= 13.7, < 13.9.0 13.6.12, 13.9.0 Fixed

Affected products

ProductAffected versionsFixed in
entrust nshield 5c firmware < 13.6.12 13.6.12
entrust nshield 5c firmware >= 13.7, < 13.9.0 13.9.0
entrust nshield hsmi firmware < 13.6.12 13.6.12
entrust nshield hsmi firmware >= 13.7, < 13.9.0 13.9.0
entrust nshield connect xc base firmware < 13.6.12 13.6.12
entrust nshield connect xc base firmware >= 13.7, < 13.9.0 13.9.0
entrust nshield connect xc mid firmware < 13.6.12 13.6.12
entrust nshield connect xc mid firmware >= 13.7, < 13.9.0 13.9.0
entrust nshield connect xc high firmware < 13.6.12 13.6.12
entrust nshield connect xc high firmware >= 13.7, < 13.9.0 13.9.0

References