CVE-2025-62675 An Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting') vulnerability [CWE-113] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.4, FortiOS 7.4 all versions, FortiO...
MediumCVSS 4.3
EPSS 0.27%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: partial
- Technology
- Network Appliances
Description
An Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting') vulnerability [CWE-113] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.4, FortiOS 7.4 all versions, FortiOS 7.2 all versions, FortiProxy 7.6.0 through 7.6.4, FortiProxy 7.4 all versions, FortiProxy 7.2 all versions may allow an attacker in possession of a valid web filter override token to inject arbitrary headers via tricking a user into clicking on a crafted link.
Upgrade path
4 packages: 3 fixed, 1 with no fix yet.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Siemens RUGGEDCOM APE1808 | All versions | No fix listed | No fix yet |
| fortinet fortios | >= 6.4.0, <= 6.4.16; >= 7.0.0, <= 7.0.19; >= 7.2.0, < 7.6.5; >= 7.2.0, <= 7.2.13 +2 more | 7.6.5 | Fixed |
| fortinet fortipam | = 1.2.0; = 1.7.0; >= 1.0.0, <= 1.0.3; >= 1.1.0, <= 1.1.2 +4 more | after 1.0.3, 1.1.2, 1.3.1, 1.4.3, 1.5.1, 1.6.2 | Fixed |
| fortinet fortiproxy | >= 7.0.0, <= 7.0.23; >= 7.2.0, < 7.6.5; >= 7.2.0, <= 7.2.16; >= 7.4.0, <= 7.4.14 +1 more | 7.6.5 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| fortinet fortios | >= 7.6.0, <= 7.6.4 | No fix listed |
| fortinet fortios | >= 7.4.0, <= 7.4.12 | No fix listed |
| fortinet fortios | >= 7.2.0, <= 7.2.13 | No fix listed |
| fortinet fortios | >= 7.0.0, <= 7.0.19 | No fix listed |
| fortinet fortios | >= 6.4.0, <= 6.4.16 | No fix listed |
| fortinet fortipam | = 1.7.0 | No fix listed |
| fortinet fortipam | >= 1.6.0, <= 1.6.2 | No fix listed |
| fortinet fortipam | >= 1.5.0, <= 1.5.1 | No fix listed |
| fortinet fortipam | >= 1.4.0, <= 1.4.3 | No fix listed |
| fortinet fortipam | >= 1.3.0, <= 1.3.1 | No fix listed |
| fortinet fortipam | = 1.2.0 | No fix listed |
| fortinet fortipam | >= 1.1.0, <= 1.1.2 | No fix listed |
| fortinet fortipam | >= 1.0.0, <= 1.0.3 | No fix listed |
| fortinet fortiproxy | >= 7.6.0, <= 7.6.4 | No fix listed |
| fortinet fortiproxy | >= 7.4.0, <= 7.4.14 | No fix listed |
| fortinet fortiproxy | >= 7.2.0, <= 7.2.16 | No fix listed |
| fortinet fortiproxy | >= 7.0.0, <= 7.0.23 | No fix listed |
| Siemens RUGGEDCOM APE1808 | All versions | No fix listed |
| fortinet fortiproxy | >= 7.2.0, < 7.6.5 | 7.6.5 |
| fortinet fortios | >= 7.2.0, < 7.6.5 | 7.6.5 |
References
- https://fortiguard.fortinet.com/psirt/FG-IR-26-152 vendor-advisory
- cert-portal.siemens.com
- ENISA EUVD EUVD-2025-210465 third-party-advisory