Skip to content

CVE-2025-69426 Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded SSH Credentials RCE

CriticalCVSS 10.0 EPSS 0.40%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
No known exploitation · automatable: yes · technical impact: total
Technology
Docker

Description

The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise.

Upgrade path

1 package: 1 fixed.

PackageAffectedFixed inStatus
Ruckus Networks vRIoT IOT Controller >= 2.3.0.0 (GA), < 3.0.0.0 (GA); >= 2.3.1.0 (MR), < 3.0.0.0 (GA); >= 2.4.0.0 (GA), < 3.0.0.0 (GA) 3.0.0.0 (GA) Fixed

Affected products

ProductAffected versionsFixed in
Ruckus Networks vRIoT IOT Controller >= 2.3.0.0 (GA), < 3.0.0.0 (GA) 3.0.0.0 (GA)
Ruckus Networks vRIoT IOT Controller >= 2.3.1.0 (MR), < 3.0.0.0 (GA) 3.0.0.0 (GA)
Ruckus Networks vRIoT IOT Controller >= 2.4.0.0 (GA), < 3.0.0.0 (GA) 3.0.0.0 (GA)

References