CVE-2026-124760 Alarm receiver stops delivering alarms after a malformed alarm notification

LowCVSS 2.3 EPSS 0.22%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
No known exploitation · automatable: no · technical impact: partial

Description

P-Net before 1.0.4 sets the alarm receiver state to waiting for confirmation before the data of a received alarm notification is parsed. If the parsing fails the state is not restored, and later alarm notifications of the same priority are discarded without acknowledge until the Application Relationship is released. The Application Relationship and the cyclic data exchange keep working. The attacker must be able to send an alarm notification in the context of an established Application Relationship and requires ADJACENT network access.

Upgrade path

1 package: 1 fixed.

PackageAffectedFixed inStatus
RT-Labs AB P-Net < 1.0.4 1.0.4 Fixed

Affected products

ProductAffected versionsFixed in
RT-Labs AB P-Net < 1.0.4 1.0.4