CVE-2026-126227 A unintended proxy or intermediary ('confused deputy') vulnerability in Fortinet FortiAnalyzer 8.0.0 through 8.0.1, FortiAnalyzer 7.6.0 through 7.6.7, FortiAnalyzer 7.4.0 through 7.4.11, FortiAnalyzer...
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: total
- Technology
- Network Appliances
Description
A unintended proxy or intermediary ('confused deputy') vulnerability in Fortinet FortiAnalyzer 8.0.0 through 8.0.1, FortiAnalyzer 7.6.0 through 7.6.7, FortiAnalyzer 7.4.0 through 7.4.11, FortiAnalyzer 7.2.0 through 7.2.12, FortiAnalyzer Cloud 8.0.1, FortiAnalyzer Cloud 7.6.0 through 7.6.7, FortiAnalyzer Cloud 7.4.1 through 7.4.11, FortiAnalyzer Cloud 7.2.1 through 7.2.12, FortiManager 8.0.0 through 8.0.1, FortiManager 7.6.0 through 7.6.7, FortiManager 7.4.0 through 7.4.11, FortiManager 7.2.0 through 7.2.12, FortiManager Cloud 8.0.1, FortiManager Cloud 7.6.0 through 7.6.7, FortiManager Cloud 7.4.1 through 7.4.11, FortiManager Cloud 7.2.1 through 7.2.12 may allow an authenticated attacker to execute commands outside of the intended scope via specially crafted HTTP request
Upgrade path
4 packages: 4 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| fortinet fortianalyzer | >= 7.2.0, <= 7.2.12; >= 7.4.0, <= 7.4.11; >= 7.6.0, <= 7.6.7; >= 8.0.0, <= 8.0.1 | after 7.2.12, 7.4.11, 7.6.7, 8.0.1 | Fixed |
| fortinet fortianalyzercloud | = 8.0.1; >= 7.2.1, <= 7.2.12; >= 7.4.1, <= 7.4.11; >= 7.6.0, <= 7.6.7 | after 7.2.12, 7.4.11, 7.6.7 | Fixed |
| fortinet fortimanager | >= 7.2.0, <= 7.2.12; >= 7.4.0, <= 7.4.11; >= 7.6.0, <= 7.6.7; >= 8.0.0, <= 8.0.1 | after 7.2.12, 7.4.11, 7.6.7, 8.0.1 | Fixed |
| fortinet fortimanagercloud | = 8.0.1; >= 7.2.1, <= 7.2.12; >= 7.4.1, <= 7.4.11; >= 7.6.0, <= 7.6.7 | after 7.2.12, 7.4.11, 7.6.7 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| fortinet fortimanager | >= 8.0.0, <= 8.0.1 | No fix listed |
| fortinet fortimanager | >= 7.6.0, <= 7.6.7 | No fix listed |
| fortinet fortimanager | >= 7.4.0, <= 7.4.11 | No fix listed |
| fortinet fortimanager | >= 7.2.0, <= 7.2.12 | No fix listed |
| fortinet fortianalyzer | >= 8.0.0, <= 8.0.1 | No fix listed |
| fortinet fortianalyzer | >= 7.6.0, <= 7.6.7 | No fix listed |
| fortinet fortianalyzer | >= 7.4.0, <= 7.4.11 | No fix listed |
| fortinet fortianalyzer | >= 7.2.0, <= 7.2.12 | No fix listed |
| fortinet fortimanagercloud | = 8.0.1 | No fix listed |
| fortinet fortimanagercloud | >= 7.6.0, <= 7.6.7 | No fix listed |
| fortinet fortimanagercloud | >= 7.4.1, <= 7.4.11 | No fix listed |
| fortinet fortimanagercloud | >= 7.2.1, <= 7.2.12 | No fix listed |
| fortinet fortianalyzercloud | = 8.0.1 | No fix listed |
| fortinet fortianalyzercloud | >= 7.6.0, <= 7.6.7 | No fix listed |
| fortinet fortianalyzercloud | >= 7.4.1, <= 7.4.11 | No fix listed |
| fortinet fortianalyzercloud | >= 7.2.1, <= 7.2.12 | No fix listed |
References
- https://fortiguard.fortinet.com/psirt/FG-IR-26-242
- ENISA EUVD EUVD-2026-123875 third-party-advisory