Skip to content

CVE-2026-16675 Rockwell Automation FactoryTalk® Activation Manager - Privilege Escalation

HighCVSS 8.5 EPSS 0.14%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
No known exploitation · automatable: no · technical impact: total

Description

A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources.

Upgrade path

1 package: 0 fixed.

PackageAffectedFixed inStatus
Rockwell Automation FactoryTalk® Activation Manager = Version 5.02 and below No fix listed Versions listed

Affected products

ProductAffected versionsFixed in
Rockwell Automation FactoryTalk® Activation Manager = Version 5.02 and below No fix listed