Description
IBM Power Systems Firmware FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in host firmware NVRAM parsing. An attacker with root access to a guest partition on an OpenPOWER system can write a specially crafted NVRAM image, causing the host firmware boot stage to crash with possible memory corruption. This condition persists until operator intervention — clearing NVRAM via the service processor — to restore normal operation. This vulnerability only affects OpenPOWER systems; systems running PowerVM are not affected. Successful exploitation results in an integrity and availability impact to the managed system.
Upgrade path
11 packages: 11 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| ibm power hardware management console 7063-cr2 firmware | >= op940, < op940.82 | op940.82 | Fixed |
| ibm power system ac922 8335-gth firmware | >= op940, < op940.a2 | op940.a2 | Fixed |
| ibm power system ac922 8335-gtx firmware | >= op940, < op940.a2 | op940.a2 | Fixed |
| ibm power system e950 9040-mr9 firmware | >= fw950.00, < fw950.h3 | fw950.h3 | Fixed |
| ibm power system e980 9080-m9s firmware | >= fw950.00, < fw950.h3 | fw950.h3 | Fixed |
| ibm power system h922 9223-22s firmware | >= fw950.00, < fw950.h3 | fw950.h3 | Fixed |
| ibm power system h924 9223-42s firmware | >= fw950.00, < fw950.h3 | fw950.h3 | Fixed |
| ibm power system s914 9009-41g firmware | >= fw950.00, < fw950.h3 | fw950.h3 | Fixed |
| ibm power system s922 9009-22g firmware | >= fw950.00, < fw950.h3 | fw950.h3 | Fixed |
| ibm power system s924 9009-42g firmware | >= fw950.00, < fw950.h3 | fw950.h3 | Fixed |
| ibm power systems firmware | >= FW950.00, <= FW950.H2; >= OP940.00, <= OP940.81; >= OP940.00, <= OP940.a1 | after FW950.H2, OP940.81, OP940.a1 | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| ibm power systems firmware | >= FW950.00, <= FW950.H2 | No fix listed |
| ibm power systems firmware | >= OP940.00, <= OP940.a1 | No fix listed |
| ibm power systems firmware | >= OP940.00, <= OP940.81 | No fix listed |
| ibm power system s922 9009-22g firmware | >= fw950.00, < fw950.h3 | fw950.h3 |
| ibm power system h922 9223-22s firmware | >= fw950.00, < fw950.h3 | fw950.h3 |
| ibm power system s914 9009-41g firmware | >= fw950.00, < fw950.h3 | fw950.h3 |
| ibm power system s924 9009-42g firmware | >= fw950.00, < fw950.h3 | fw950.h3 |
| ibm power system h924 9223-42s firmware | >= fw950.00, < fw950.h3 | fw950.h3 |
| ibm power system e950 9040-mr9 firmware | >= fw950.00, < fw950.h3 | fw950.h3 |
| ibm power system e980 9080-m9s firmware | >= fw950.00, < fw950.h3 | fw950.h3 |
| ibm power system ac922 8335-gth firmware | >= op940, < op940.a2 | op940.a2 |
| ibm power system ac922 8335-gtx firmware | >= op940, < op940.a2 | op940.a2 |
| ibm power hardware management console 7063-cr2 firmware | >= op940, < op940.82 | op940.82 |
References
- www.ibm.com patch vendor-advisory
- ENISA EUVD EUVD-2026-62696 third-party-advisory